Data Sheet
Table 28. Interrupt Active, Register Address 0x0A
Bit No.
7
6
5
4
3
2
1
0
Table 29. Charger Status 1, Register Address 0x0B
Bit No.
7
6
5
4
3
[2:0]
Bit Name
Not used
THERM_LIM_INT
WD_INT
TSD_INT
THR_INT
BAT_INT
CHG_INT
VIN_INT
Bit Name
VIN_OV
VIN_OK
VIN_ILIM
THERM_LIM
CHDONE
CHARGER_STATUS[2:0]
Access
R
R
R
R
R
R
R
Access
R
R
R
R
R
R
Default
0
0
0
0
0
0
0
Default
N/A
N/A
N/A
N/A
N/A
N/A
Rev. 0 | Page 33 of 44
Description
1 = indicates an interrupt caused by isothermal charging.
1 = indicates an interrupt caused by the watchdog alarm. The
watchdog timer expires within 2 sec or 4 sec, depending on the
watch dog period setting of 32 sec or 64 sec, respectively.
1 = indicates an interrupt caused by an overtemperature fault.
1 = indicates an interrupt caused by THR temperature thresholds.
1 = indicates an interrupt caused by battery voltage thresholds.
1 = indicates an interrupt caused by a charger mode change.
1 = indicates an interrupt caused by VINx voltage thresholds.
Description
1 = the voltage at the VINx pins exceeds V
1 = the voltage at the VINx pins exceeds V
1 = the current into a VINx pin is limited by the high voltage blocking
FET and the charger is not running at the full programmed I
1 = the charger is not running at the full programmed I
limited by the die temperature.
1 = the end of a charge cycle has been reached. This bit latches on,
in that it does not reset to low when the V
Charger status bus.
000 = off.
001 = trickle charge.
010 = fast charge (CC mode).
011 = fast charge (CV mode).
100 = charge complete.
101 = LDO mode.
110 = trickle or fast charge timer expired.
111 = battery detection.
VIN_OV
VIN_OK_RISE
RCH
threshold is breached.
.
, V
VIN_OK_FALL
ADP5062
CHG
but is
CHG
.
.