ICE3BR0665J Infineon Technologies, ICE3BR0665J Datasheet - Page 29

no-image

ICE3BR0665J

Manufacturer Part Number
ICE3BR0665J
Description
IC OFFLINE CTRLR SMPS OTP 8DIP
Manufacturer
Infineon Technologies
Series
CoolSET®F3Rr
Datasheet

Specifications of ICE3BR0665J

Output Isolation
Isolated
Frequency Range
56.5 ~ 73.5kHz
Voltage - Input
10.5 ~ 27 V
Voltage - Output
650V
Power (watts)
74W
Operating Temperature
-25°C ~ 130°C
Package / Case
8-DIP (0.300", 7.62mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SP000417880

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICE3BR0665J
Manufacturer:
EPSON
Quantity:
2 100
Part Number:
ICE3BR0665J
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
ICE3BR0665J
0
Company:
Part Number:
ICE3BR0665J
Quantity:
4 800
Company:
Part Number:
ICE3BR0665J
Quantity:
10 000
Company:
Part Number:
ICE3BR0665J
Quantity:
39
Part Number:
ICE3BR0665JF
Manufacturer:
INFINEON
Quantity:
3 400
Part Number:
ICE3BR0665JXKLA1
Manufacturer:
SEMELAB
Quantity:
101
Part Number:
ICE3BR0665JZ
Manufacturer:
INFINEON
Quantity:
479
Part Number:
ICE3BR0665JZ
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
9
Figure 35
General guideline for PCB layout design using F3/F3R CoolSET
1. “Star Ground “at bulk capacitor ground, C11:
Guideline for PCB layout design when >3KV lightning surge test applied (refer to Figure 35):
1. Add spark gap
Version 2.0
2. High voltage traces clearance:
3. Filter capacitor close to the controller ground:
a. Spark Gap 3 and Spark Gap 4, input common mode choke, L1:
a. 400V traces (positive rail of bulk capacitor C11) to nearby trace: > 2.0mm
b. 600V traces (drain voltage of CoolSET
a. DC ground of the primary auxiliary winding in power transformer, TR1, and ground of C16 and Z11.
b. DC ground of the current sense resistor, R12
c. DC ground of the CoolSET
d. DC ground from bridge rectifier, BR1
e. DC ground from the bridging Y-capacitor, C4
High voltage traces should keep enough spacing to the nearby traces. Otherwise, arcing would incur.
Spark Gap 1
Spark Gap 2
Spark gap is a pair of saw-tooth like copper plate facing each other which can discharge the accumulated
Gap separation is around 1.5mm (no safety concern)
charge during surge test through the sharp point of the saw-tooth plate.
Filter capacitors, C13, C14 and C15 should be placed as close to the controller ground and the controller pin
as possible so as to reduce the switching noise coupled into the controller.
“Star Ground “means all primary DC grounds should be connected to the ground of bulk capacitor C11
separately in one point. It can reduce the switching noise going into the sensitive pins of the CoolSET
effectively. The primary DC grounds include the followings.
of IC12 should be connected to the GND pin of IC11 and then “star “connect to the bulk capacitor ground.
GND
L
N
FUSE1
Schematic for recommended PCB layout
Y-CAP
Schematic for recommended PCB layout
C2
X-CAP
C1
C3
Y-CAP
Spark Gap 4
Spark Gap 3
F3 CoolSET schematic for recommended PCB layout
L1
®
C4
Y-CAP
device, GND pin of IC11; the signal grounds from C13, C14, C15 and collector
BR1
®
C11
IC11) to nearby trace: > 2.5mm
R12
C13
bulk cap
*
BA
GND
D11
CS
C14
IC11
CoolSET
F3
FB
29
Schematic for recommended PCB layout
C15
DRAIN
VCC
NC
®
R11
R13
Z11
(refer to Figure 35):
R14
D11
C16
D13
C12
TR1
IC12
D21
R23
CoolSET
C21
R22
C23
ICE3BR0665J
IC21
C22
R25
R21
R24
10 Jun 2008
®
®
-F3R
GND
device
Vo

Related parts for ICE3BR0665J