ADE7752ARZ Analog Devices Inc, ADE7752ARZ Datasheet

no-image

ADE7752ARZ

Manufacturer Part Number
ADE7752ARZ
Description
IC ENERGY METERING DETEC 24-SOIC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADE7752ARZ

Input Impedance
450 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
6mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-SOIC (0.300", 7.50mm Width)
Meter Type
3 Phase
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7752ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
FEATURES
High accuracy, supports 50 Hz/60 Hz IEC62053-2x
Less than 0.1% error over a dynamic range of 500 to 1
Compatible with 3-phase/3-wire delta and 3-phase/4-wire
The ADE7752
High frequency output CF is intended for calibration and
Logic output REVP indicates a potential miswiring or
Direct drive for electromechanical counters and 2-phase
Proprietary ADCs and DSP provide high accuracy over large
On-chip power supply monitoring
On-chip creep protection (no load threshold)
On-chip reference 2.4 V ±8% (20 ppm/°C typical) with
Single 5 V supply, low power
Low cost CMOS process
GENERAL DESCRIPTION
The ADE7752 is a high accuracy polyphase electrical energy
measurement IC. The ADE7752A is a pin-to-pin compatible
low power version of ADE7752. The functions of ADE7752 and
Rev. C
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice.
No license is granted by implication or otherwise under any patent or patent rights of Analog
Devices. Trademarks and registered trademarks are the property of their respective owners.
Wye configurations
outputs F1 and F2
supplies instantaneous real power
negative power for each phase
stepper motors (F1 and F2)
variations in environmental conditions and time
external overdrive capability
60 mW typical: ADE7752
30 mW typical: ADE7752A
1
supplies average real power on frequency
VBP
VCP
VAP
IAN
IBP
IBN
ICP
ICN
IAP
VN
16
15
10
14
13
5
6
7
8
9
2.4V REF
AGND
11
4k Ω
REF
ADC
ADC
ADC
ADC
ADC
ADC
Figure 1. 24-Lead Standard Small Outline Package [SOIC]
12
IN/OUT
FUNCTIONAL BLOCK DIAGRAM
CORRECTION
CORRECTION
CORRECTION
PHASE
PHASE
PHASE
HPF
HPF
HPF
Φ
Φ
Φ
REVP
Polyphase Energy Metering IC
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.461.3113
ADE7752A are the same. Both products are referred to in the
text of this data sheet as ADE7752.
The part specifications surpass the accuracy requirements as
quoted in the IEC62053-2x standard. The only analog circuitry
used in the ADE7752 is in the analog-to-digital converters (ADCs)
and reference circuit. All other signal processing (such as multi-
plication, filtering, and summation) is carried out in the digital
domain. This approach provides superior stability and accuracy
over extremes in environmental conditions and over time.
The ADE7752 supplies average real power information on the
low frequency outputs, F1 and F2. These logic outputs may be
used to directly drive an electromechanical counter or to
interface with an MCU. The CF logic output gives instanta-
neous real power information. This output is intended to be
used for calibration purposes.
The ADE7752 includes a power supply monitoring circuit on
the V
voltage on V
pulses are issued on F1, F2, and CF. Internal phase matching
circuitry ensures that the voltage and current channels are
phase matched. An internal no load threshold ensures the part
does not exhibit any creep when there is no load. The ADE7752
is available in a 24-lead SOIC package.
1
4
Patent pending.
LPF
LPF
LPF
SCF
DD
DIGITAL-TO-FREQUENCY CONVERTER
18
pin. The ADE7752 remains inactive until the supply
S0
21
X
X
X
ABS
DD
17
S1
22
reaches 4 V. If the supply falls below 4 V, no
Σ
F2
23
ADE7752/
ADE7752A
ADE7752/ADE7752A
MONITOR
SUPPLY
POWER
© 2005 Analog Devices, Inc. All rights reserved.
V
F1
24
DD
3
with Pulse Output
CF
1
19
20
2
DGND
CLKIN
CLKOUT
www.analog.com

Related parts for ADE7752ARZ

ADE7752ARZ Summary of contents

Page 1

FEATURES High accuracy, supports 50 Hz/60 Hz IEC62053-2x Less than 0.1% error over a dynamic range of 500 to 1 Compatible with 3-phase/3-wire delta and 3-phase/4-wire Wye configurations 1 The ADE7752 supplies average real power on frequency outputs F1 and ...

Page 2

ADE7752/ADE7752A TABLE OF CONTENTS Specifications..................................................................................... 3 Timing Characteristics..................................................................... 4 Absolute Maximum Ratings............................................................ 5 ESD Caution.................................................................................. 5 Pin Configuration and Function Descriptions............................. 6 Typical Performance Characteristics ............................................. 8 Test Circuit ...................................................................................... 10 Terminology .................................................................................... 11 Theory of Operation ...................................................................... 12 Power ...

Page 3

SPECIFICATIONS ± 5%, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz Table 1. Parameter Min 1, 2 ACCURACY Measurement Error on Current Channel Phase Error Between Channels PF = 0.8 ...

Page 4

ADE7752/ADE7752A TIMING CHARACTERISTICS ± 5%, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz Table 2. Parameter Conditions and F2 Pulse Width (Logic High Output Pulse ...

Page 5

ABSOLUTE MAXIMUM RATINGS T = 25°C, unless otherwise noted. A Table 3. Parameter V to AGND DGND DD Analog Input Voltage to AGND VAP, VBP, VCP, VN, IAP, IAN, IBP, IBN, ICP, and ICN Reference Input Voltage ...

Page 6

ADE7752/ADE7752A PIN CONFIGURATION AND FUNCTION DESCRIPTIONS Table 4. Pin Function Descriptions Pin No. Mnemonic Description 1 CF Calibration Frequency Logic Output. The CF logic output gives instantaneous real power information. This output is intended to be used for calibration purposes. ...

Page 7

Pin No. Mnemonic Description 19 CLKIN Master Clock for ADCs and Digital Signal Processing. An external clock can be provided at this logic input. Alternatively, a parallel resonant AT crystal can be connected across CLKIN and CLKOUT to provide a ...

Page 8

ADE7752/ADE7752A TYPICAL PERFORMANCE CHARACTERISTICS 0.5 WYE CONNECTION ON-CHIP REFERENCE 0.4 0.3 PHASE C 0.2 0.1 PHASE B 0 –0.1 –0.2 –0.3 –0.4 –0.5 0.1 1 CURRENT CHANNEL (% of Full Scale) Figure 4. Error as a Percent of Reading with ...

Page 9

WYE CONNECTION ON-CHIP REFERENCE 0.4 0 0.2 0.1 0 –0.1 –0.2 –0.3 –0.4 –0 FREQUENCY (Hz) Figure 10. Error as a Percent of Reading over Frequency with an Internal Reference (Wye Connection) ...

Page 10

ADE7752/ADE7752A TEST CIRCUIT 1MΩ 220V 1kΩ 100nF 10μ LOAD ABS DD 1kΩ IAP ADE7752/ 33nF RB ADE7752A 1kΩ IAN 33nF CLKOUT 20 IBP 7 SAME AS ...

Page 11

TERMINOLOGY Measurement Error The error associated with the energy measurement made by the ADE7752 is defined by the following formula: ⎧ Energy Registered by ADE = ⎨ Percentage Error ⎩ True Energy Error Between Channels The high-pass filter (HPF) in ...

Page 12

ADE7752/ADE7752A THEORY OF OPERATION The six voltage signals from the current and voltage transducers are digitized with ADCs. These ADCs are 16-bit second-order ∑-Δ with an oversampling rate of 833 kHz. This analog input structure greatly simplifies transducer interface by ...

Page 13

This is the correct real power calculation. INSTANTANEOUS POWER SIGNAL V× CURRENT VOLTAGE INSTANTANEOUS POWER SIGNAL V× I × cos(60° VOLTAGE 60° Figure 16. DC Component of Instantaneous Power Signal Conveys Real Power Information PF ...

Page 14

ADE7752/ADE7752A ANALOG INPUTS CURRENT CHANNELS The voltage outputs from the current transducers are connected to the ADE7752 current channels, which are fully differential voltage inputs. IAP, IBP, and ICP are the positive inputs for IAN, IBN, and ICN, respectively. The ...

Page 15

TYPICAL CONNECTION DIAGRAMS CURRENT CHANNEL CONNECTION Figure 19 shows a typical connection diagram for the current channel (IA). A current transformer (CT) is the current trans- ducer selected for this example. Notice the common-mode voltage for the current channel is ...

Page 16

ADE7752/ADE7752A Figure 21 shows the connections of the analog inputs of the ADE7752 with the power lines in a 3-phase 3-wire delta service. Note that only two current inputs and two voltage inputs of the ADE7752 are used in this ...

Page 17

POWER SUPPLY MONITOR The ADE7752 contains an on-chip power supply monitor. The power supply ( continuously monitored by the ADE7752 the supply is less than 4 V ± 5%, the outputs of the ADE7752 are inactive. ...

Page 18

ADE7752/ADE7752A DIGITAL-TO-FREQUENCY CONVERSION After multiplication, the digital output of the low-pass filter contains the real power information of each phase. Because this LPF is not an ideal brick wall filter implementation, however, the output signal also contains attenuated components at ...

Page 19

MODE SELECTION OF THE SUM OF THE THREE ACTIVE ENERGIES The ADE7752 can be configured to execute the arithmetic sum of the three active energies ϕA sum of the absolute value of these energies |Wh ...

Page 20

ADE7752/ADE7752A TRANSFER FUNCTION FREQUENCY OUTPUTS F1 AND F2 The ADE7752 calculates the product of six voltage signals (on current channel and voltage channel) and then low-pass filters this product to extract real power information. This real power information is then ...

Page 21

As the voltage and current inputs respect Equations 5 and 6, the total real power ( − − + − ⎛ ...

Page 22

ADE7752/ADE7752A SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION As shown in Table 5, the user can select one of seven frequen- cies. This frequency selection determines the maximum frequency on F1 and F2. These outputs are intended to be ...

Page 23

NEGATIVE POWER INFORMATION The ADE7752 detects when the current and voltage channels of any of the three phase inputs have a phase difference greater than 90°: ϕ or ϕ or ϕ > 90°. This mechanism can detect ...

Page 24

... OUTLINE DIMENSIONS 0.30 (0.0118) 0.10 (0.0039) COPLANARITY 0.10 ORDERING GUIDE Model Temperature Range ADE7752AR -40° 85°C ADE7752ARRL -40° 85°C 1 ADE7752ARZ -40° 85°C 1 ADE7752ARZ-RL -40° 85°C ADE7752AAR -40° 85°C ADE7752AAR-RL -40° 85°C 1 ADE7752AARZ -40° 85°C 1 ADE7752AARZ-RL -40° 85°C EVAL-ADE7752EB EVAL-ADE7752AEB Pb-free part. ...

Related keywords