MC33982BPNA Freescale Semiconductor, MC33982BPNA Datasheet - Page 20

IC SWITCH HI SIDE SINGLE 16-PQFN

MC33982BPNA

Manufacturer Part Number
MC33982BPNA
Description
IC SWITCH HI SIDE SINGLE 16-PQFN
Manufacturer
Freescale Semiconductor
Type
High Sider
Datasheet

Specifications of MC33982BPNA

Input Type
SPI
Number Of Outputs
1
On-state Resistance
2 mOhm
Voltage - Supply
6 V ~ 27 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-PQFN, 16-PowerQFN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Current - Output / Channel
-
Current - Peak Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC33982BPNA
Manufacturer:
FREESCALE
Quantity:
6 500
Part Number:
MC33982BPNA
Manufacturer:
FREESCALE
Quantity:
6 500
Part Number:
MC33982BPNA
Manufacturer:
FREESCALE
Quantity:
20 000
FAULT MODE
driving the
• Over-temperature fault
• Over-voltage and under-voltage fault
• Open load fault
OVER-TEMPERATURE FAULT (NON-LATCHING)
shutdown circuitry in the output structure. Over-temperature
detection is enabled when the output is in the ON state.
results in the faulted output turning OFF until the temperature
falls below the T
until action is taken by the MCU to shut OFF the output, or
until the offending load is removed.
in the status register and cleared after either a valid SPI read
or a power reset of the device.
OVER-VOLTAGE FAULT (NON-LATCHING)
fault (OVF) condition on the VPWR pin. The output remains
in the OFF state until the over-voltage condition is removed.
When experiencing this fault, the OVF fault bit is set in bit
OD1 and cleared after either a valid SPI read or a power reset
of the device.
disabled through the SPI (bit OV_dis).
UNDER-VOLTAGE SHUTDOWN (LATCHING OR
NON-LATCHING)
6.0 V. As long as the V
specified range, the internal logic states within the device will
be sustained.
under-voltage threshold, (VPWRUV) the output will turn off,
FS will go to Logic [0], and the fault register UVF bit will be set
to 1.
recovers:
20
33982
FUNCTIONAL DEVICE OPERATION
PROTECTION AND DIAGNOSIS FEATURES
The 33982 indicates the following faults as they occur by
The 33982 incorporates over-temperature detection and
For the output, an over-temperature fault (OTF) condition
When experiencing this fault, the OTF fault bit will be set
The 33982 shuts down the output during an over-voltage
The over-voltage protection and diagnostic can be
The output(s) will latch off at some battery voltage below
In the cases where the battery voltage drops below the
Two cases need to be considered when the battery level
• If the output(s) command is (are) low, FS will go to
• If the output command is ON, then FS will remain at
Logic [1], but the UVF bit will remain set to 1 until the
next read operation.
Logic [0]. The output must be turned OFF and ON again
FS
pin to Logic [0]:
SD(HYS)
DD
. This cycle will continue indefinitely
level stays within the normal
PROTECTION AND DIAGNOSIS FEATURES
• Over-current fault (high and low)
fault condition is removed, except for over-current and in
some cases under-voltage.
available (and reset) via the SO pin during the first valid SPI
communication (refer to
SPI (bit UV_dis = 1). In this case, the FS and UVF bits do not
report any under-voltage fault condition and the output state
will not be changed as long as the battery voltage does not
drop any lower than 2.5 V.
OPEN LOAD FAULT (NON-LATCHING)
the output. Output open load fault (OLF) is detected and
reported as a fault condition when the output is disabled
(OFF). The open load fault is detected and latched into the
status register after the internal gate voltage is pulled low
enough to turn OFF the output. The OLF fault bit is set in the
status register. If the open load fault is removed, the status
register will be cleared after reading the register.
(bit OL_dis). It is recommended to disable the open load
detection circuitry (OL_dis bit sets to logic [1]) in case of a
permanent open load fault condition.
OVER-CURRENT FAULT (LATCHING)
detection levels (I
high detection levels (I
The two selectable, simultaneously active over-current
detection levels, defined by I
Figure
(I
current low detection level and the over-current condition
exceeds the programmed over-current time period (t
device will latch the output OFF.
then the device will immediately latch the fault and turn OFF
the output, regardless of the selected t
until the device is commanded OFF and then ON again.
OCL0
The
Fault information is retained in the fault register and is
The under-voltage protection can be disabled through the
The 33982 incorporates open load detection circuitry on
The open load protection can be disabled through the SPI
The 33982 has eight programmable over-current low
If the load current level ever reaches the selected over-
If at any time the current reaches the selected I
For both cases, the device output will stay off indefinitely
to re-enable the state of output and release FS. The
UVF bit will remain set to 1 until the next read operation.
: I
6. The eight different over-current low detection levels
FS
OCL7
pin will automatically return to Logic [1] when the
) are likewise illustrated in
OCL
) and two programmable over-current
OCH
Analog Integrated Circuit Device Data
Table
) for maximum device protection.
OCH
17).
and I
Freescale Semiconductor
OCL
OCL
Figure
, are illustrated in
driver.
6.
OCH
OC
x
level,
), the

Related parts for MC33982BPNA