L6228PD STMicroelectronics, L6228PD Datasheet - Page 15

IC DRIVER STEP MOTOR 36-PWRSOIC

L6228PD

Manufacturer Part Number
L6228PD
Description
IC DRIVER STEP MOTOR 36-PWRSOIC
Manufacturer
STMicroelectronics
Type
Driverr
Datasheet

Specifications of L6228PD

Applications
Stepper Motor Driver
Number Of Outputs
1
Current - Output
1.4A
Voltage - Supply
8 V ~ 52 V
Operating Temperature
-25°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
36-PowerSOIC
Operating Current
10mA
Operating Temperature Classification
Automotive
Package Type
PowerSO
Operating Supply Voltage (min)
8V
Operating Supply Voltage (typ)
48V
Operating Supply Voltage (max)
52V
Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
8 V to 52 V
Supply Current
1.4 A
Mounting Style
SMD/SMT
For Use With
497-6818 - EVAL BOARD FOR L6228Q
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Compliant
Other names
497-5351-5
L6228PD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6228PD
Manufacturer:
ST
0
Part Number:
L6228PD
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
L6228PD
Quantity:
2 500
Part Number:
L6228PD.
Manufacturer:
ST
0
Part Number:
L6228PD013TR
Manufacturer:
ST
0
Part Number:
L6228PD013TR
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6228PDTR
Manufacturer:
ST
0
Part Number:
L6228PDTR
Manufacturer:
ST
Quantity:
150
Part Number:
L6228PDTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6228PDTR
0
Company:
Part Number:
L6228PDTR
Quantity:
3 300
time. The drive mode is selected by the HALF/FULL input and the current state of the sequence generator as
described below. A rising edge of the CLOCK input advances the state machine to the next state. The direction
of rotation is set by the CW/CCW input. The RESET input resets the state machine to state.
HALF STEP MODE
A HIGH logic level on the HALF/FULL input selects Half Step Mode. Figure 16 shows the motor current wave-
forms and the state diagram for the Phase Sequencer Generator. At Start-Up or after a RESET the Phase Se-
quencer is at state 1. After each clock pulse the state changes following the sequence 1,2,3,4,5,6,7,8,… if CW/
CCW is high (Clockwise movement) or 1,8,7,6,5,4,3,2,… if CW/CCW is low (Counterclockwise movement).
NORMAL DRIVE MODE (Full-step two-phase-on)
A LOW level on the HALF/FULL input selects the Full Step mode. When the low level is applied when the state
machine is at an ODD numbered state the Normal Drive Mode is selected. Figure Fig. 17 shows the motor cur-
rent waveform state diagram for the state machine of the Phase Sequencer Generator. The Normal Drive Mode
can easily be selected by holding the HALF/FULL input low and applying a RESET. AT start -up or after a RE-
SET the State Machine is in state1. While the HALF/FULL input is kept low, state changes following the se-
quence 1,3,5,7,… if CW/CCW is high (Clockwise movement) or 1,7,5,3,… if CW/CCW is low (Counterclockwise
movement).
WAVE DRIVE MODE (Full-step one-phase-on)
A LOW level on the pin HALF/FULL input selects the Full Step mode. When the low level is applied when the
state machine is at an EVEN numbered state the Wave Drive Mode is selected. Figure 18 shows the motor cur-
rent waveform and the state diagram for the state machine of the Phase Sequence Generator. To enter the
Wave Drive Mode the state machine must be in an EVEN numbered state. The most direct method to select the
Wave Drive Mode is to first apply a RESET, then while keeping the HALF/FULL input high apply one pulse to
the clock input then take the HALF/FULL input low. This sequence first forces the state machine to sate 1. The
clock pulse, with the HALF/FULL input high advances the state machine from state 1 to either state 2 or 8 de-
pending on the CW/CCW input. Starting from this point, after each clock pulse (rising edge) will advance the
state machine following the sequence 2,4,6,8,… if CW/CCW is high (Clockwise movement) or 8,6,4,2,… if CW/
CCW is low (Counterclockwise movement).
Figure 16. Half Step Mode
Figure 17. Normal Drive Mode
Start Up or Reset
Start Up or Reset
3
2
1
3
2
1
4
8
4
8
5
6
7
5
6
7
D01IN1320
D01IN1322
CLOCK
CLOCK
I
I
OUTA
OUTB
I
I
OUTA
OUTB
1
1
3
2
5
3
7
4
1
5
3
6
5
7
7
8
L6228
15/26

Related parts for L6228PD