Specifications of MAX6698UE38+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Full Temp Accuracy
+/- 3.5 C, +/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 3. SMBus Write Timing Diagram
Figure 4. SMBus Read Timing Diagram
Table 2. Main Temperature Register (High
Byte) Data Format
SMBCLK
SMBDATA
7-Channel Precision Remote-Diode, Thermistor,
SMBCLK
SMBDATA
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
Diode fault (open)
Diode fault (short)
t
SU:STA
TEMP (°C)
t
SU:STA
<0.00
>127
0.00
127
126
A
25
t
HD:STA
A
t
HD:STA
_______________________________________________________________________________________
t
LOW
t
LOW
B
t
HIGH
B
t
HIGH
1111 1111 or 1110 1110
t
SU:DAT
DIGITAL OUTPUT
t
C
SU:DAT
0111 1111
0111 1111
0111 1110
0000 0000
0000 0000
1111 1111
C
00011001
and Local Temperature Monitor
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
D
D
E
F
E
F
Table 3. Extended Resolution
Temperature Register (Low Byte) Data
Format
t
HD:DAT
G
G
TEMP (°C)
+0.125
+0.250
+0.375
+0.500
+0.625
+0.725
+0.875
0
I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
H
H
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
I
I
J K
J
K
DIGITAL OUTPUT
000X XXXX
001X XXXX
010X XXXX
011X XXXX
100X XXXX
101X XXXX
110X XXXX
111X XXXX
t
SU:STO
t
SU:STO
L
L
t
BUF
t
BUF
M
M
9