S-875041CUP-ACCT2G Seiko Instruments, S-875041CUP-ACCT2G Datasheet - Page 13

no-image

S-875041CUP-ACCT2G

Manufacturer Part Number
S-875041CUP-ACCT2G
Description
IC VOLT DETECT/REG 5.0V SOT89-5
Manufacturer
Seiko Instruments
Datasheet

Specifications of S-875041CUP-ACCT2G

Applications
Converter, Constant Voltage Power Supply
Voltage - Input
1.3 ~ 24 V
Number Of Outputs
1
Voltage - Output
5V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
SOT-89-5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4. S-873325B
*1. t
*2. Excluding the charging current of C
Rev.8.0
Voltage Regulator
Output voltage
I/O voltage difference
Line regulation
Load regulation
Input voltage
Temperature
coefficient of V
Voltage Detector
Operating voltage
Delay time
Temperature
characteristic of − V
Detection voltage
Sink current
Leakage current
Hysteresis width
Total
Current consumption
pd
(ms) = (3.18 min., 5.74 typ., 8.73 max.) × C
HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION
_00
Item
*1
OUT
DET
*2
Δ
Symbol
Δ V
Δ V
Δ
− V
I
V
V
Δ
Δ
I
V
V
DOUT
V
V
LEAK
I
t
OUT
HYS
Ta
Ta
SS
OUT1
OUT2
pd
V
OUT
opr
DET
dif
IN
DET
D
Nch,
V
V
I
V
I
V
I
V
Ta =− 40°C to + 85°C
C
Ta =− 40°C to + 85°C
Nch,
V
V
OUT
OUT
OUT
DS
IN
IN
IN
IN
DS
IN
D
= 4.7 nF
= 0.5 V, V
= 5.3 V, I
= 4.3 to 24 V,
= 5.3 V,
= 5.3 V, I
= 5.3 V, Unloaded
= 24 V, V
Seiko Instruments Inc.
= 30 mA
= 30 mA
= 50 μ A to 40 mA
D
Condition
(nF)
Table 9
OUT
OUT
IN
IN
= 1.3 V
= 10 V
= 30 mA
= 30 mA,
3.220
2.440
− V
× 0.03
0.25
Min.
1.3
15
DET
(Unless otherwise specified: Ta = 25°C)
3.300
± 0.25
2.500
Typ.
0.45
± 0.2
0.60
15
15
27
4
3.380
± 1.00
2.560
− V
× 0.08
Max.
0.70
± 0.8
0.1
50
50
24
24
41
8
DET
S-87x Series
Unit
mV
mV
mV
mA
/°C
/°C
ms
μ A
μ A
V
V
V
V
V
circuit
Test
1
2
3
2
4
2
5
13

Related parts for S-875041CUP-ACCT2G