HCPL-2211 Avago Technologies US Inc., HCPL-2211 Datasheet - Page 13

OPTOCOUPLER LOGIC-OUT 5MBD 8-DIP

HCPL-2211

Manufacturer Part Number
HCPL-2211
Description
OPTOCOUPLER LOGIC-OUT 5MBD 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2211

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
25mA
Data Rate
5MBd
Propagation Delay High - Low @ If
150ns @ 3mA
Current - Dc Forward (if)
10mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
No. Of Channels
1
Isolation Voltage
3.75kV
Optocoupler Output Type
Logic Gate
Input Current
5mA
Output Voltage
20V
Opto Case Style
DIP
No. Of Pins
8
Propagation Delay Low-high
0.3µs
Forward Voltage
1.5V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
516-1059-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-2211
Manufacturer:
AVAGO
Quantity:
5 000
Part Number:
HCPL-2211
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-2211#300E
Manufacturer:
AVAGO
Quantity:
10 000
Part Number:
HCPL-2211#500E
Manufacturer:
AVAGO
Quantity:
10 000
Part Number:
HCPL-2211-000E
Manufacturer:
AVAGO
Quantity:
5 000
Part Number:
HCPL-2211-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-2211-060E
Manufacturer:
AVAGO
Quantity:
5 000
Part Number:
HCPL-2211-060E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-2211-300E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-2211-360E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Package Characteristics
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment level
safety specification or Avago Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage,” publication number 5963-2203
Notes:
10. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥4500 V rms for one second (leakage
11. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥6000 V rms for one second (leakage
12. For HCPL-2231/32 only. Measured between pins 1 and 2, shorted together, and pins 3 and 4, shorted together.
13
1. Each channel.
2. Derate total package power dissipation, P
3. Duration of output short circuit time should not exceed 10 ms.
4. For single devices, input capacitance is measured between pin 2 and pin 3.
5. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together and pins 5, 6, 7, and 8 shorted together.
6. The t
7. CM
8. For HCPL-2202/12, V
9. Use of a 0.1 µF bypass capacitor connected between pins 5 and 8 is recommended.
Withstand
Voltage
Parameter
Input-Output Momentary
Input-Output Resistance
Input-Output Capacitance
Input-Input Insulation
Leakage Current
Resistance (Input-Input)
Capacitance (Input-Input)
the output pulse. The t
trailing edge of the output pulse.
CM
detection current limit, I
EN/DIN EN 60747-5-2 Insulation Characteristics Table, if applicable.
detection current limit, I
EN/DIN EN 60747-5-2 Insulation Characteristics Table.
H
L
is the maximum slew rate of the common mode voltage that can be sustained with the output voltage in the logic low state, V
is the maximum slew rate of the common mode voltage that can be sustained with the output voltage in the logic high state, V
PLH
*
propagation delay is measured from the 50% point on the leading edge of the input pulse to the 1.3 V point on the leading edge of
HCNW22XX
HCNW22XX
HCNW22XX
O
is on pin 6.
PHL
I-O
I-O
propagation delay is measured from the 50% point on the trailing edge of the input pulse to the 1.3 V point on the
≤5 µA). This test is performed before the 100% production test for partial discharge (Method b) shown in the IEC/
≤5 µA). This test is performed before the 100% production test for partial discharge (Method b) shown in the IEC/
Sym.
V
R
C
R
C
I
ISO
I-I
I-O
I-O
I-I
I-I
T
, linearly above 70°C free-air temperature at a rate of 4.5 mW/°C.
3750
5000
Min.
10
10
12
11
0.005
0.25
Typ.
10
10
10
0.6
0.5
12
13
11
Max.
0.6
t = 5 s, V
V rms
Units
µA
pF
pF
Ω
Ω
I-I
= 500 V
RH < 50%, t = 1 min.
T
T
T
T
Relative Humidity = 45%,
V
f = 1 MHz
A
A
A
A
I-I
= 25°C
= 25°C
= 100°C
= 25°C, V
= 500 V
Test Conditions
I-O
= 0 Vdc
V
f = 1 MHz,
I-O
= 500 Vdc
Fig.
O
O
< 0.8 V.
5, 10
5, 11
> 2.0 V.
Note
12
12
12
5
5

Related parts for HCPL-2211