ACPL-214-500E Avago Technologies US Inc., ACPL-214-500E Datasheet

ISOLATOR 3KVRMS 1CH TRANS SO-4

ACPL-214-500E

Manufacturer Part Number
ACPL-214-500E
Description
ISOLATOR 3KVRMS 1CH TRANS SO-4
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-214-500E

Output Type
Transistor
Input Type
AC, DC
Package / Case
SO-4
Mounting Type
Surface Mount
Voltage - Output
80V
Number Of Channels
1
Current - Output / Channel
50mA
Current - Dc Forward (if)
±50mA
Voltage - Isolation
3000Vrms
Vce Saturation (max)
400mV
Current Transfer Ratio (max)
400% @ ±1mA
Current Transfer Ratio (min)
20% @ ±1mA
Maximum Fall Time
3 us
Maximum Input Diode Current
1 mA
Maximum Rise Time
2 us
Output Device
Phototransistor
Configuration
1 Channel
Maximum Collector Emitter Voltage
80 V
Maximum Collector Emitter Saturation Voltage
0.4 V
Isolation Voltage
3000 Vrms
Current Transfer Ratio
20 %
Maximum Forward Diode Voltage
1.4 V
Maximum Collector Current
50 mA
Maximum Power Dissipation
200 mW
Maximum Operating Temperature
+ 110 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-214-500E
Manufacturer:
AVAGO
Quantity:
972
Part Number:
ACPL-214-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
ACPL-214
AC Input, Half-Pitch Phototransistor Optocoupler
Data Sheet
Description
The ACPL-214 is an AC-input single channel half-pitch
phototransistor optocoupler which contains 2 light
emitting diodes connected inversely parallel & optically
coupled to a phototransistor. It is packaged in a 4-pin SO
package.
The input-output isolation voltage is rated at 3000 Vrms.
Response time, tr, is 2μs typically, while minimum CTR is
20% at input current of 1 mA
ACPL-214 pin layout
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
4
4
1
1
Lead (Pb) Free
RoHS 6 fully
compliant
3
3
2
2
Pin 1
Pin 2
Pin 3
Pin 4
Anode
Cathode
Emitter
Collector
Features
• Current transfer ratio
• High input-output isolation voltage
• Non-saturated Response time
• SO package
• CMR 10kV/μs (typical)
• Safety and regulatory approvals
• Options available:
Applications
• I/O Interface for Programmable controllers,
• Sequence controllers
• System appliances, measuring instruments
• Signal transmission between circuits of diff erent
(CTR: 20% (min) at I
(V
(tr: 2μs (typ) at V
- cUL
- IEC/EN/DIN EN 60747-5-2
– CTR Ranks 0, A
computers.
potentials and impedances.
ISO
= 3,000V
RMS
CC
)
= 10V, I
F
= ±1mA, V
C
= 2mA, R
CC
= 5V)
L
= 100Ω)

Related parts for ACPL-214-500E

ACPL-214-500E Summary of contents

Page 1

... RoHS 6 fully compliant RoHS 6 fully compliant options available; -xxxE denotes a lead-free product Description The ACPL-214 is an AC-input single channel half-pitch phototransistor optocoupler which contains 2 light emitting diodes connected inversely parallel & optically coupled to a phototransistor packaged in a 4-pin SO package. The input-output isolation voltage is rated at 3000 Vrms. ...

Page 2

... Example 1: ACPL-214-560E to order product of SO-4 Surface Mount package in Tape & Reel packaging with IEC/EN/DIN EN 60767-5-2 Safety Approval, 20%<CTR<400% and RoHS compliant. Example 2: ACPL-214-50AE to order product of SO-4 Surface Mount package in Tape & ...

Page 3

... Operating Temperature Average Forward Current Pulse Forward Current LED Power Dissipation Collector Current Collector-Emitter Voltage Emitter-Collector Voltage Isolation Voltage (AC for 1min, R.H. 40~60%) Collector Power Dissipation Total Power Dissipation Lead Solder Temperature 3 Symbol ACPL-214 Units °C T -55~125 S °C T -55~110 A I ±50 mA F(AVG) I ± ...

Page 4

Electrical Specifi cations Over recommended ambient temperature at 25ºC unless otherwise specifi ed. Parameter Symbol Forward Voltage V F Terminal Capacitance C t Collector Dark Current I CEO Collector-Emitter Breakdown BV Voltage Emitter-Collector Breakdown BV Voltage Current Transfer Ratio CTR ...

Page 5

... Pulse width Ta = 25° 0.1000 1.0000 0.4 Figure 6. Forward Current vs. Forward Voltage 1000 100 100 0.5 (mA) F Figure 8. Pulse Forward Current vs. Pulse Forward Voltage ACPL-214 100 Ambient Temperature, Ta (°C) -30°C 0°C 25°C 50°C 75° 110°C 0.6 0.8 1.0 1.2 1.4 1 ...

Page 6

Collector-Emitter Voltage, Vce(V) Figure 9. Collector Current vs. Collector-Emitter Voltage 0.1 0.01 0.001 0.0001 0.0001 0.001 Forward Current, I Figure 11. Collector Current vs. Forward Current 1000 100 10 ...

Page 7

Ambient Temperature, Ta (°C) Figure 15. Collector Current vs. Ambient Temperature 100 16mA 1.9kΩ L 0.1 - Ambient Temperature, ...