SMART2600RM2U Tripp Lite, SMART2600RM2U Datasheet - Page 3

no-image

SMART2600RM2U

Manufacturer Part Number
SMART2600RM2U
Description
UPS 2600VA 2100W 9OUT RKMT/TOWER
Manufacturer
Tripp Lite
Series
Smart Pro®r
Type
Power Supply Regulatorr
Datasheets

Specifications of SMART2600RM2U

Rohs Status
Not applicable
Power - Rated
2.6kVA / 2100W
Ac Outlets
9 (UPS)
Features
Expandable
Backup Time - Max Load
6 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 20A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA 5-20P
Connector - Ac Output
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-20R
Size
19.00" L x 17.50" W x 3.50" H (482.6mm x 444.5mm x 88.9mm)
Weight
64 lbs (29kg)
Ac Output Connector
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-20R
Brand/series
SmartPro®
Capacity
2600 VA
Color
Black
Communication
DB9, RJ11, USB
Current, Rating
24 A (Max.)
Dimensions
8.89cmH×44.5cmW×48.3cmD
Frequency, Output
60 Hz
Input Type
NEMA 5-20P
Length, Cord
10 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(4) NEMA 5-15R, (4) NEMA 5-15/20R, (1) NEMA L5-20R
Power, Rating
2100 W
Standards
cUL, UL Listed
Temperature, Operating
0 to +40 °C
Time, Backup
4 min.
Voltage Regulation
120 V (Sine Wave Output) within ± 5% @ Battery Mode
Voltage, Battery
48 VDC
Voltage, Input
120 V
Voltage, Nominal
120 VAC (Output)
Voltage, Output
120 VAC
Voltage, Supply
2100/2600 W/VA
Media Lines Protected
-
Lead Free Status / Rohs Status
RoHS Compliant part
Switched PDU options
External PDU
redundancy options
Output AC waveform (AC
mode)
Output AC waveform
(battery mode)
INPUT
Rated input current (at
maximum load)
Nominal Input Voltage(s)
Supported
UPS input connection
type
Input circuit breaker
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical
Service
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
Expandable battery
runtime
External battery pack
compatibility
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
PDUMH20ATNET
*Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS
models only
Sine wave
Pure Sine wave
24A (with user-supplied L5-30P plug), 16A (with factory 5-20P plug)
120V AC
5-20P
30A
10
3
20A 120V
4 min. (2100w)
11 min. (1050w)
Extended runtime supported via optional external battery packs
BP48V24-2U
48
Less than 4.5 hours from 10% to 90%
RBC94-2U
Front panel battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Input voltages between 127 and 147 are reduced by 12%
Input voltages between 95 and 104 are boosted by 12%
Input voltages between 83 and 94 are boosted by 24%
(limit 1); BP48V60RT3U (multi-pack compatible)
(1U / 16 5-15/20R outlets)*;
PDUMV20NET
(0U / 24 5-15/20R outlets)