HLMP-3651 Avago Technologies US Inc., HLMP-3651 Datasheet - Page 5
HLMP-3651
Manufacturer Part Number
HLMP-3651
Description
LED 5MM 12V 583NM YELLOW DIFF
Manufacturer
Avago Technologies US Inc.
Datasheet
1.HLMP-1640.pdf
(9 pages)
Specifications of HLMP-3651
Viewing Angle
60°
Package / Case
Radial - 2 Lead
Color
Yellow
Millicandela Rating
2.2mcd
Current - Test
13mA
Wavelength - Dominant
585nm
Wavelength - Peak
583nm
Lens Type
Diffused, Yellow Tinted
Lens Style/size
Round, 5mm, T-1 3/4
Height
8.81mm
Mounting Type
Through Hole
Resistance Tolerance
585nm
Led Size
T-1 3/4
Illumination Color
Yellow
Lens Color/style
Tinted Diffused
Operating Voltage
12 V
Wavelength
585 nm
Luminous Intensity
2.2 mcd
Operating Current
13 mA
Lens Dimensions
5 mm
Lens Shape
Dome
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Forward (vf) Typ
-
Luminous Flux @ Current - Test
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
516-1342
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
HLMP-3651
Manufacturer:
AVAGO
Quantity:
40 000
Company:
Part Number:
HLMP-3651
Manufacturer:
AVAGO
Quantity:
50 000
Figure 1. Forward current vs. applied forward voltage. 5 volt devices.
Figure 3. Maximum allowed applied forward voltage vs.
ambient temperature Rq
Figure 5. Relative luminous intensity vs. angular displacement for T-1
package.
5
90°
80°
70°
7.5
24
20
16
12
60°
8
4
0
8
6
4
2
0
0
0
50°
V
CC
T
2
A
40°
– APPLIED FORWARD VOLTAGE – V
– AMBIENT TEMPERATURE – °C
20
4
30°
6
20°
JA
40
7.5
= 175°C/W. 5 volt devices.
8
10°
10
60
0°
12
1.0
0.8
0.6
0.4
0.2
10°
14
20°
80
15
85
30°
16
40°
50°
60°
70°
80°
90°
100°
Figure 2. Forward current vs. applied forward voltage. 12 volt devices.
Figure 4. Maximum allowed applied forward voltage vs.
ambient temperature Rq
Figure 6. Relative luminous intensity vs. angular displacement for T-1
package.
90°
80°
70°
24
20
16
12
16
15
12
60°
8
4
0
8
4
0
0
0
50°
V
CC
T
2
40°
A
– APPLIED FORWARD VOLTAGE – V
– AMBIENT TEMPERATURE – °C
20
4
30°
6
20°
JA
40
7.5
= 175°C/W. 12 volt devices.
8
10°
10
60
0°
0.8
0.6
0.4
0.2
12
1.0
10°
14
20°
80
15
85
30°
16
40°
50°
60°
70°
80° 90°
3
/
4
100°