... VSK-S3-3R3U 3.3V/700mA VSK-S3-5U 5V/600mA VSK-S3-9U 9V/330mA VSK-S3-12U 12V/250mA VSK-S3-15U 15V/200mA VSK-S3-24U 24V/125mA INPUT parameter conditions/description input frequency input voltage output power derated from 85-90 VAC input current AC input of 110 VAC AC input of 230 VAC inrush current measured at 110 VAC at full load, cold start ...
... PART NUMBER: VSK-S3-XXU PROTECTION CIRCUIT parameter conditions/description over temperature 150 ºC max. over voltage chip lock up GENERAL parameter conditions/description operating temp. storage temp. case temp. power derating above 55°C humidity storage humid. non-condensing isolation voltage applied for 1 minute (HI-POT) primary to secondary, 500 Vdc @ 100 MΩ ...
... VSK-S3-5U VSK-S3-9U VSK-S3-12U VSK-S3-15U VSK-S3-24U Note! 1. Output filtering capacitors C1 electrolytic capacitors recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C2 ceramic capacitors , it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (when converter fails). ...