NKE0503SC Murata Power Solutions Inc, NKE0503SC Datasheet - Page 2

CONV DC/DC 1W 5VIN 3.3V SIP SGL

NKE0503SC

Manufacturer Part Number
NKE0503SC
Description
CONV DC/DC 1W 5VIN 3.3V SIP SGL
Manufacturer
Murata Power Solutions Inc
Series
NKEr
Type
Isolatedr
Datasheet

Specifications of NKE0503SC

Number Of Outputs
1
Output
3.3V
Power (watts)
1W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 5.5V
Package / Case
4-SIP Module
1st Output
3.3 VDC @ 303mA
Size / Dimension
0.45" L x 0.24" W x 0.29" H (11.4mm x 6.1mm x 7.4mm)
Power (watts) - Rated
1W
Operating Temperature
-40°C ~ 85°C
Efficiency
74%
Approvals
cUL, UL
Output Power
1 W
Input Voltage Range
4.5 V to 5.5 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
303 mA
Isolation Voltage
3 KV
Package / Case Size
SIP
Output Voltage
3.3 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1432-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NKE0503SC
Manufacturer:
TI
Quantity:
6 000
1. 12V input types have typically 3% less load regulation.
OUTPUT CHARACTERISTICS
Parameter
Rated Power
Voltage Set Point Accuracy
Line regulation
Load Regulation
Ripple and Noise
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
GENERAL CHARACTERISTICS
Parameter
Switching frequency
TEMPERATURE CHARACTERISTICS
Parameter
Specifi cation
Storage
Case temperature rise above
ambient
Cooling
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NKE series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 1000V DC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NKE series has been recognized by Underwriters Laboratory for functional insulation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation sys-
tem. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materi-
als, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specifi ed test voltage.
SAFETY APPROVAL
The NKE series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85ºC and/or case temperature
limit of 130ºC. Case temperature measured on the face opposite the pins. File number E179522 applies.
www.murata-ps.com
1
Conditions
T
See tolerance envelope
High V
10% load to rated load, 3.3V output types & 0309
10% load to rated load, 5V output types
10% load to rated load, 9V output types
10% load to rated load, 12V output types
10% load to rated load, 15V output types
BW=DC to 20MHz, 3.3V output types & 0305, 0505SEC, 0505DEC
BW=DC to 20MHz, other 5V output types
BW=DC to 20MHz, 9V output types
BW=DC to 20MHz, 12V output types
BW=DC to 20MHz, 15V output types
Conditions
Flash tested for 1 second
Viso= 1000VDC
Conditions
All output types
Conditions
All output types
0505D/S, 1205D/S
All other output types
Free air convection
A
=-40°C to 120°C, see derating graphs
IN
to low V
IN
Isolated Sub-Miniature 1W Single Output DC/DC Converters
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
3000
Min.
Min.
Min.
Min.
-40
-50
2010-07-14 KDC_NKE.K01 Page 2 of 7
Typ.
Typ.
Typ.
Typ.
115
1.0
7.5
6.5
6.0
10
12
40
77
43
35
32
10
NKE Series
Max.
Max.
Max.
Max.
100
130
1.0
1.2
9.5
8.5
15
15
10
80
90
65
55
85
41
32
mV p-p
Units
Units
Units
Units
%/%
VDC
kHz
°C
%
W

Related parts for NKE0503SC