BWR-15/275-D5A-C Murata Power Solutions Inc, BWR-15/275-D5A-C Datasheet - Page 3

CONV DC/DC +/-15V +/-275MA DIP

BWR-15/275-D5A-C

Manufacturer Part Number
BWR-15/275-D5A-C
Description
CONV DC/DC +/-15V +/-275MA DIP
Manufacturer
Murata Power Solutions Inc
Series
BWRr
Type
Isolatedr
Datasheet

Specifications of BWR-15/275-D5A-C

Number Of Outputs
2
Output
±15V
Power (watts)
8W
Mounting Type
Through Hole
Voltage - Input
4.7 ~ 7.25V
Package / Case
5-DIP Module
1st Output
15 VDC @ 275mA
2nd Output
-15 VDC @ 275mA
Size / Dimension
2.00" L x 1.00" W x 0.38" H (50.8mm x 25.4mm x 9.7mm)
Power (watts) - Rated
8W
Operating Temperature
-40°C ~ 100°C
Efficiency
79%
Approvals
cUL, UL
Output Power
4 W
Input Voltage Range
4.7 V to 7.25 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
+/- 15 V
Output Current (channel 1)
+/- 275 mA
Output Voltage (channel 2)
15 V
Output Current (channel 2)
+/- 275 mA
Isolation Voltage
1.5 KV
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1722-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BWR-15/275-D5A-C
Manufacturer:
HONGFA
Quantity:
34 000
Part Number:
BWR-15/275-D5A-C
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
Performance/Functional Specifications
Typical @ T
however they may not meet all listed specifications.
internally upon request. Contact MPS Applications Engineering for details.
Input Voltage Range:
Input Current
Input Filter Type
Reverse-Polarity Protection
V
Temperature Coefficient
Ripple/Noise (20MHz BW)
Line/Load Regulation
Efficiency
Isolation Voltage
Isolation Capacitance
Current Limiting
Overvoltage Protection
Transient Response (50% load step)
Switching Frequency
Operating Temperature (ambient):
Storage Temperature
Dimensions
Shielding
Case Connection:
Case Material
Pin Material
Weight
Flammability
OUT
D5A Models
D12A Models
D48A Models
±5V Outputs
±12/15V Outputs
Without Derating
With Derating
D5A and D12A Models
D48A Models
These power converters require a minimum 20% loading on each output to maintain
specified regulation. Operation under no-load conditions will not damage these devices;
Application-specific internal input/output filtering can be recommended or perhaps added
Devices can be screened or modified for higher guaranteed isolation voltages.
Contact MPS Applications Engineering for details.
D5A Models: Zener/transorb only
Accuracy (50% load):
A
= +25°C under nominal line voltage and full-load conditions, unless noted.
Dynamic Characteristics
Environmental
Physical
Output
Input
4.7-7.25 Volts (5V nominal)
9-18 Volts (12V nominal)
18-75 Volts (48V nominal)
See Ordering Guide
Pi
Yes (Instantaneous, 6A maximum)
±1.5%, maximum
±1%, maximum
±0.02% per °C
See Ordering Guide
See Ordering Guide
See Ordering Guide
1500Vdc, minimum (functional)
200pF
Auto-recovery
Zener/transorb clamps, magnetic feedback
200μsec max. to ±1.5% of final value
165kHz (±15kHz)
–40 to +65/70°C (Model dependent)
to +100°C (See Derating Curves)
–40 to +105°C
2" x 1" x 0.375" (51 x 25 x 9.5mm)
5-sided
Pin 2 (–V
Pin 1 (+V
Corrosion resistant steel with
non-conductive, epoxy-based black
enamel finish and palstic baseplate
RoHS: Gold-plated copper alloy with nickel
underplate
Non-RoHS: Solder-coated brass
1.3 ounces (37 grams)
UL 94V-0
IN
IN
)
www.murata-ps.com
)
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "floating." Any
BWR model may be configured to produce an output of 10V, 24V or 30V (for
±5V, ±12V or ±15V models, respectively) by applying the load across the
+Output and –Output pins (pins 3 and 5), with either output grounded. The
Common pin (pin 4) should be left open. Minimum 20% loading is recom-
mended under these conditions.
Filtering and Noise Reduction
All A-Series BWR 7-10 Watt DC/DC Converters achieve their rated ripple
and noise specifications without the use of external input/output capacitors.
In critical applications, input/output ripple and noise may be further reduced
by installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. Output
capacitors should be connected between their respective output pin (pin 3 or
5) and Common (pin 4) as shown in Figure 2. The caps should be located
as close to the power converters as possible. Typical values are listed in the
tables below. In many applications, using values greater than those listed
will yield better results.
In critical, space-sensitive applications, MPS may be able to tailor the inter-
nal input/output filtering of these units to meet your specific requirements.
Contact our Applications Engineering Group for additional details.
T E C H N I C A L
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied.
Input Voltage:
Input Reverse-Polarity Protection
Output Overvoltage Protection
Output Current
Storage Temperature
Lead Temperature (soldering, 10 sec.)
To Reduce Input Ripple
To Reduce Output Ripple
7 - 1 0 W , D u a l O u t p u t D C / D C C o n v e r t e r s
D5 Models
D12 Models
D48 Models
±5V Outputs
±12V Outputs
±15V Outputs
"D5A" Models
"D12A" Models
"D48A" Models
±5V Output
±12/15V Outputs
Technical enquiries email: sales@murata-ps.com, tel:
N O T E S
Absolute Maximum Ratings
47μF, 10V
20μF, 35V
10μF, 100V
47μF, 10V, Low ESR
22μF, 20V, Low ESR
10 Volts
20 Volts
80Volts
Current must be <6A. Brief
duration only. Fusing recommended.
13 Volts, limited duration
28 Volts, limited duration
36 Volts, limited duration
Current limited. Max. current and
short-circuit duration are model
dependent.
–40 to +105°C
+300°C
BWR Models
MDC_BWR7_10_B01 Page 3 of 6
+1 508 339 3000

Related parts for BWR-15/275-D5A-C