AK1301-7R POWER ONE, AK1301-7R Datasheet - Page 3

CONV INPUT 8-35VDC OUTPUT 12V

AK1301-7R

Manufacturer Part Number
AK1301-7R
Description
CONV INPUT 8-35VDC OUTPUT 12V
Manufacturer
POWER ONE
Series
Kr
Type
Isolatedr
Datasheet

Specifications of AK1301-7R

Output
12V
Number Of Outputs
1
Power (watts)
150W
Mounting Type
Surface Mount
Voltage - Input
8 ~ 35V
Package / Case
Module
1st Output
12 VDC @ 10A
Size / Dimension
6.60" L x 4.40" W x 3.20" H (168mm x 111mm x 80mm)
Power (watts) - Rated
120W
Efficiency
80%
Approvals
CE, cUL, TUV, UL
Output Power
150 W
Input Voltage Range
8 V to 35 V
Input Voltage (nominal)
15 V
Output Voltage (channel 1)
12 V
Output Current (channel 1)
10 A
Package / Case Size
168 mm x 111 mm x 80 mm
Output Type
Isolated
Output Voltage
12 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q1792212
Operating input voltage V
Number of outputs (4 = single, 5 = double) ................... 4, 5
Single-output models:
Nominal voltage output 1 (main output), V
Double-output models:
Nominal voltage output 1 and 2
Operational ambient temperature range T
Auxiliary functions and options:
Example: LK5540-9EPD3T B1: Power factor corrected AC-DC converter, operating input voltage range 85 – 264 VAC,
Part Number Description
Product Marking
Basic type designation, applicable approval marks, CE
mark, warnings, pin designation, Power-One patents and
company logo, identification of LEDs, test sockets, and
potentiometer.
Specific type designation, input voltage range, nominal
output voltages and currents, degree of protection, batch
no., serial no., and data code including production site,
modification status, and date of production.
BCD20001-G Rev AC, 16-Dec-2010
1
2
3
4
5
6
Customer-specific models
Option E is mandatory for all -9 models. Models with -5E or -6E are functional down to –40 °C.
Feature R excludes option P and vice versa. Option P is not available for battery charger models.
Option D excludes option V and vice versa; option V is available for models with 5.1 V output only (LK4003, etc.).
Option K is available for models with 5.1 V output only (LK4002, LK4003, etc.) to ensure compatibility with LK1001 models.
G is always placed at the end of the part number.
85 – 264 VAC ............................................................ LK
187 – 255 VAC ........................................................ LKP
5.1 V ..................................................................... 0, 1, 2
12 V ............................................................................. 3
15 V ......................................................................... 4, 5
24 V ............................................................................. 6
Other voltages
Other specifications (single-output models)
12 V, 12 V
15 V, 15 V
24 V, 24 V ................................................................... 60
Other specifications or additional features
–25 to 71 °C ............................................................... -7
–40 to 71 °C ................................................................ -9
–25
–25
Other
Inrush current limitation ............................................. E
Output voltage control input ....................................... R
Potentiometer (output voltage adjustment) ................ P
Undervoltage monitor (D0 – DD, to be specified) ...... D
ACFAIL signal (V2, V3, to be specified) .................... V
Current share .............................................................. T
H15S4 connector (rather then H15S2) ..................... K
Cooling plate standard case ............................ B or B1
Cooling plate for long case 220 mm
RoHS-compliant for all 6 substances ...................... G
2
2
to 60 °C .............................................................. -6
to 50 °C .............................................................. -5
2 electrically isolated outputs, each providing 15 V, 5 A, equipped with inrush current limiter, a potentiometer to
adjust the output voltages, undervoltage monitor D3, current share feature, and a cooling plate B1.
1
......................................................................... -0
...............................................................................................
...............................................................................................
1
....................................................... 7, 8
i
:
o1 nom
1
A
:
...................... B2
1
1
.... 21 – 9 9
..... 70 – 99
Page 3 of 29
20
40
2
3
3
4
4
5
6
150 – 280 Watt AC-DC Converters
K Series with PFC Data Sheet
LK 5 5 40 -9 E P D3 T K B1
www.power-one.com

Related parts for AK1301-7R