HLS30ZG-NT POWER ONE, HLS30ZG-NT Datasheet
HLS30ZG-NT
Specifications of HLS30ZG-NT
Related parts for HLS30ZG-NT
HLS30ZG-NT Summary of contents
Page 1
... High efficiencies and a unique copper-core printed circuit board design create superior thermal characteristics that enhance product reliability and eliminate the need for a heat sink. Model Selection Input Model Voltage VDC HLS30ZG 36-75 HLS30ZE 36-75 HLS30ZD 36-75 36-75 ...
Page 2
Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long- term reliability, and cause permanent damage to the converter. Parameter Input voltage Operating Temperature Storage Temperature ON/OFF Control Voltage Environmental, Mechanical & ...
Page 3
... HLS30 HLS40 (Tboad temp) =-40°C to +100°C) Note: *** 50-75% load step change to 1% error band Iout.max, Nom Vin Vout≤0.97Vout.nom HLS30ZD HLS30ZG & HLS30ZE HLS40ZA & HLS40ZB Over all input voltage and load conditions Iout.max, Vin = Vnom Page Min Nom Max ...
Page 4
Feature Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Negative Logic (-N suffix) On/Off (pin #3) (Primary side ref. to -Vin) Positive Logic (-P suffix) On/Off (pin #3) (Primary side ref. ...
Page 5
... Characteristic Curves: Figure 1. HLS30ZG (5V) Efficiency vs. Output Load Figure 2. HLS30ZE (3.3V) Efficiency vs. Output Load Figure 3. HLS30ZD (2.5V) Efficiency vs. Output Load FEB 17, 2006 revised to JUL 25, 2006 HLS Series DC-DC Converter Data Sheet 48 VDC Input, 30 & 40 Amp Half-Bricks Output Current, A Figure 4. HLS40ZA (1.5V) Efficiency vs. Output Load ...
Page 6
Typical Application Figure 6 shows the recommended connections for the HLS Series converter. Figure 6. Typical Application of HLS Series The HLS Series converters do not require any external components for proper operation. However, if the distribution of the input ...
Page 7
... R trim-up = (------------- - R2) kΩ Vo*Δ% Where R1 and R2 are constants from the table below Model R1 (kΩ) 3.077 HLS30ZG 1.690 HLS30ZE 1.039 HLS30ZD 0. 223 HLS40ZA 0.475 HLS40ZB ∗ NOTE: Δ% - Percentage output voltage trim down or up. ...
Page 8
... This is further illustrated in Fig arrow ‘A’ example, from Figure 10, the HLS30ZG operating at 55 °C can deliver reliably with 100 LFM forced air, while reliably with 200 LFM forced air. Figure 9. HLS Forced Airflow Directions ( Airflow directions ‘ ...
Page 9
... Vin = 54V, Orientation : Vin- to Vin + NC ( LFM) 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (Deg C) THERMAL DERATING CURVE HLS30ZG-NT ∆=.65A ∆=1A 100 LFM(Vin to Vo) 100 LFM(Vo to Vin Ambient Temperature (Deg C) Figure 15. Effect of Airflow Direction on Power Rating [HLS30ZG (5V) shown] www ...
Page 10
Mechanical Drawing Ordering Information Options Remote ON/OFF Trim Pin Length NOTES: 1. Consult factory for the complete list of available options. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as ...