OKY2-T/16-W5N-C Murata Power Solutions Inc, OKY2-T/16-W5N-C Datasheet
OKY2-T/16-W5N-C
Specifications of OKY2-T/16-W5N-C
Related parts for OKY2-T/16-W5N-C
OKY2-T/16-W5N-C Summary of contents
Page 1
... Ordering Guide, Model Numbering Mechanical Specifi cations, Input/Output Pinout Detailed Electrical Specifi cations Output Voltage Adjustment, Soldering Guidelines Application Notes Performance Data and Oscillograms – OKY2-T/16-W5 Tape and Reel Information Simplifi ed Block Diagram Controller Reference and Error Amplifier Figure 1 ...
Page 2
... OKY-T/16-W5N-C 0.7525-3.63 16 52.8 OKY2-T/16-W5P-C 0.7525-3.63 16 52.8 OKY2-T/16-W5N-C 0.7525-3.63 16 52.8 ➀ Efficiency is shown at Vout=1V.. ➁ All specifications are at nominal line voltage, Vout=nominal (3.3V) and full load, +25 deg.C. unless otherwise noted. Output capacitors are 1 μF ceramic and 10 μF electrolytic in parallel. Input cap is 22 μF. See detailed specifications. ...
Page 3
... The Remote On/Off can be provided with either positive (P suffi negative (N suffi x) polarity. ** Vtrack Seq applies only to OKY2 models. No connection for OKY models. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page Function P66 On/Off Control * +Vin Vtrack Seq** Gnd (Common) ...
Page 4
Performance and Functional Specifi cations See Note 1 Input Input Voltage Range See Ordering Guide and Note 7. Isolation Not isolated Start-Up Voltage 2.05V (OKY-T/16-W5) Undervoltage Shutdown (see Note 15) 1.90 V (OKY-T/16-W5) Overvoltage Shutdown None Refl ected (Back) Ripple ...
Page 5
Specifi cation Notes, Cont.: (5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed ...
Page 6
APPLICATION NOTES Input Fusing Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. We recommend ...
Page 7
COPPER STRIP +OUTPUT C1 -OUTPUT COPPER STRIP C1 = 0.1μF CERAMIC C2 = 10μF TANTALUM LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 5: Measuring Output Ripple and Noise (PARD) Minimum Output Loading Requirements All models regulate within specifi cation and ...
Page 8
Dynamic control of the On/Off function should be able to sink appropriate signal current when brought low and withstand appropriate voltage when brought high. Be aware too that there is a fi nite time in milliseconds (see Specifi cations) between ...
Page 9
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25° 3.3V) OUT 100 4. 5. Load Curre nt (Amps) Output Ripple and Noise (Vin=5V, Vout=3.3V, Iout=16A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=5V, Vout=3.3V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. ...
Page 10
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25° 2.5V) OUT 100 5. Load Curre nt (Amps) Output Ripple and Noise (Vin=5V, Vout=2.5V, Iout=16A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=5V, Vout=2.5V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. ...
Page 11
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25° 1.8V) OUT 100 5. Load Curre nt (Amps) Output Ripple and Noise (Vin=5V, Vout=1.8V, Iout=16A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=5V, Vout=1.8V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. ...
Page 12
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-W5 100 Output Ripple and Noise (Vin=5V, Vout=1.5V, Iout=16A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=5V, Vout=1.5V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. Programmable DOSA-SMT 10/16-Amp DC/DC Converters Effi ciency vs. Line Voltage and Load Current @ +25° ...
Page 13
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25° 1.2V) OUT 5. Load Curre nt (Amps) Output Ripple and Noise (Vin=5V, Vout=1.2V, Iout=16A, Cload=0, ScopeBW=100MHz) Step Load Transient Response (Vin=5V, Vout=1.2V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. ...
Page 14
... PERFORMANCE DATA AND OSCILLOGRAMS – OKY2-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25° .75V) OUT 5. Load Curre nt (Amps) Maximum Current Temperature Derating vs. Airfl sea level (Vin=3.3V, Vout=2.5V, airfl ow direction is transverse) 16.25 16 15.75 15.5 15.25 Natural convection 15 100 LFM 200 LFM 14 ...
Page 15
... OKY-T/10-W5N-C OKY2-T/10-W5P-C OKY2-T/10-W5N-C OKY-T/16-W5P-C OKY-T/16-W5N-C OKY2-T/16-W5P-C OKY2-T/16-W5N-C The manufacturing date code is four characters: First character – Last digit of manufacturing year, example 2009 Second character – Month code (1 through 9 and O through D) Third character – Day code (1 through 10=O and 11 through through Z) Fourth character – Manufacturing information www ...
Page 16
TAPE & REEL IMFORMATION 2.00 .079 (P/U) 18.19 .716 (P/U) 44.00 1.732 2.00 .079 PIN #1 THIS CORNER (FARSIDE) PICKUP NOZZLE LOCATION ( 3-6mm) PICK & PLACE PICKUP (P/U) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 ...