(MAP80-4000) POWER ONE, (MAP80-4000) Datasheet - Page 3

PWR SUPPLY 80W,+-5V,+-12V OUT

(MAP80-4000)

Manufacturer Part Number
(MAP80-4000)
Description
PWR SUPPLY 80W,+-5V,+-12V OUT
Manufacturer
POWER ONE
Series
MAP80r
Datasheet

Specifications of (MAP80-4000)

Voltage - Output
±5V, ±12V
Number Of Outputs
4
Power (watts)
80W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 14A
2nd Output
12 VDC @ 4A
3rd Output
-12 VDC @ 1A
4th Output
-5 VDC @ 1A
Size / Dimension
7.2" L x 4.2" W x 1.8" H (182.9mm x 106.7mm x 45.7mm)
Power (watts) - Rated
80W
Operating Temperature
0°C ~ 50°C
Efficiency
75%
Approvals
CE, CSA, TUV, UL
Line Regulation
0.2%, 0.5%
Load Regulation
1%, 2%
Input Voltage
90 to 135|175 to 264 V
Output Voltage
5|12|-5|-12 V
Maximum Current Rating
2.5(rms) A
Maximum Output Current
14|4|1|1 A
Maximum Output Power
80 W
Input Frequency
47 to 63 Hz
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
179-2100
MAP80-4000
PW9910
MCD10144 Rev. 1.0, 02-Feb-10
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference,
Conducted
Input Transient
Protection
Insulation Resistance
Leakage Current
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Options
DESCRIPTION
Cover
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264VAC.
CONDITIONS/DESCRIPTION
Operating.
Non-operating.
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C.
0°C to 70°C (After 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
NOTES
Add ‘C’ suffix to model number or order part number 412-59585-G separately.
For convection cooled applications, derate output power to 65 watts on all multiple
output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts.
Page 3 of 4
MAP80 AC-DC Series Data Sheet
Line to ground
At 100% load:
At 50% load:
Line to line
2600
MIN
MIN
-55
B
B
B
1
7
0
0
5
(183.0mm x 107.0mm x 52.0mm)
±0.02
NOM
NOM
7.20" x 4.20" x 2.05"
2
www.power-one.com
Approved
SIZE IMPACT
±0.03
MAX
500
MAX
10k
40k
50
70
85
95
20
6
ASL Ft.
ASL Ft.
Class
UNITS
UNITS
%/°C
%RH
G
VDC
M
µA
kV
°C
°C
°C
RMS
G

Related parts for (MAP80-4000)