GLD150-12G SL Power Electronics Manufacture of Condor/Ault Brands, GLD150-12G Datasheet

PWR SPLY MED SWITCHER 150W 12V

GLD150-12G

Manufacturer Part Number
GLD150-12G
Description
PWR SPLY MED SWITCHER 150W 12V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GLD150r
Datasheet

Specifications of GLD150-12G

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
150W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 12.5A
Size / Dimension
7" L x 4.5" W x 1.7" H (177.8mm x 114.3mm x 43.2mm)
Power (watts) - Rated
150W
Efficiency
80%
Approvals
CE, CSA, IEC, UL
Line Regulation
2%
Load Regulation
2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
271-2327
• Compact 4.5” x 7” x 1.7” size
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 μA leakage
• EMI compliance to CISPR11, FCC Class B
• Power fail and remote sense standard
• Medical Approved to UL2601-1, IEC601-1/60601-1
• 2 year warranty
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
2.8 A line current maximum, at 90 Vac, 60 Hz with full rated load, power factor
.99 typical, .96 minimum. Input current harmonic content meets the require-
ments of IEC1000-3-2.
Output Power
150 W with convection cooling, 180 W with fan cooling. Peak ratings are for
60 s maximum duration, 10% duty cycle.
Efficiency
Minimum 80% at full rated load with 230 Vac Input. Approximately 3% less at
115 Vac.
Hold-Up Time
Outputs will remain within regulation limits for 25 ms minimum from loss of
ac input at full load, 10 ms before Power Fail indication.
Output Regulation
Total regulation is the maximum deviation from the nominal voltage for all
steady state loading conditions.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit.
Minimum Load
No minimum load required to maintain output specifications.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
Transient Response
Main Output - 500 μs typical response time for return to within 0.5% of final
value for a 50% load step change, di/dt< 0.2 A μs. Maximum voltage devia-
tion is 3%.
Remote Sense
Standard feature on all models, includes open sense lead protection.
Overvoltage Protection
Built in on all models.
Input Protection
Internal ac fuses provided on both lines on all units.
Voltage Adjustment
Output Voltage is adjustable +/- 5% with user adjustable potentiometer.
Temperature Coefficient
0.03% / °C typical on all outputs.
Overshoot
Less than 2% overshoot at turn-on under all conditions, less than 1% over-
shoot at turn-off under all conditions.
and CSA-C22.2 No. 601.1
All specifications are typical at nominal input, full load at 25
PERFORMANCE MEDICAL SWITCHERS
FEATURES:
GLD150 Gold Performance Medical Switchers
O
C unless otherwise stated
Inhibit
Inhibit signal is pulled to the V1 output common to reduce average output voltage
to less than 5% of nominal.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the EMC requirements of IEC601-1.
Unless otherwise stated, all tests are done at full load and 115 and 230 Vac input.
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Conducted RF Susceptibility
Voltage Sags & Surges
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first ac halfcycle under cold
start conditions. Limiting provided by internal thermistors.
Fan Output
An additional 12 Vdc, 250 mA output suitable for powering a dc fan is included in
all models. The fan output is both current limited and thermally protected.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit from prolonged over
temperature.
Power Fail
TTL / CMOS compatible output goes low (<0.5 V) 8 ms before output voltage
drops more than 4% below nominal voltage upon loss of ac power.
Power Good
TTL / CMOS compatible output goes high more than 100 ms after V1 reaches
regulation and should assure that sufficient energy is stored in the input section to
provide normal power fail/shutdown.
Medical Approvals
All models are Certified to be in compliance with the applicable requirements of
UL2601-1, CSA-C22.2 No. 601.1, IEC601-1/60601-1.
Leakage Current
70 μA, 132 Vac @ 60 Hz normal conditions. Single fault conditions, 130 μA, 254 Vac
@ 50 Hz.
Design Verification Documents
The “Gold” series has undergone rigorous review and design analysis. The follow-
ing product documentation is available upon request;
1. MTBF study
2. DVT Data
3. EMC / Susceptibility test results
150 Watt Multiple Output
COMPLIANCE LEVEL
EN55011, Class B; FCC Class B
EN61000-4-2, 6 kV contact 8 kV air
EN61000-4-3, 3V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-4-6, 3V
EN61000-4-11

Related parts for GLD150-12G

GLD150-12G Summary of contents

Page 1

... Less than 2% overshoot at turn-on under all conditions, less than 1% over- shoot at turn-off under all conditions. All specifications are typical at nominal input, full load at 25 GLD150 Gold Performance Medical Switchers Inhibit Inhibit signal is pulled to the V1 output common to reduce average output voltage to less than 5% of nominal. ...

Page 2

... Add “G” suffix to part number for RoHS compliant model. Contact factory for availability. A. Maximum continuous current rating for unrestricted convection cooling. B. Maximum continuous current rating with 150 LFM air or peak rating. C. Add “C” suffix for cover option and derate convection rating to 130 W. GLD150 MECHANICAL SPECIFICATIONS INPUT J1 MOLEX P.C.B. HEADER P/N: 39-30-2056 ...