*10. Measured by the each measuring method of UL,CSA,EN and DENAN(at 60Hz).
*11. Ratings - Derating at standard mounting.
*12. As for DENAN, built to meet at 100VAC.
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
*3. Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
*4. Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz.
*5. 85 ~ 265VAC , constant load.
*6. No load-Full load, constant input voltage.
*7. Foldback current limit with automatic recovery. Not operate at over load or dead short condition for more than 30seconds.
*8. OVP circuit will shutdown output, manual reset (Re power on).
*9. At 100/200VAC , Ta=25°C, nominal output voltage and maximum output current.
*Read instruction manual carefully, before using the power supply unit.
10 Maximum Ripple & Noise
11 Maximum Line Regulation
12 Maximum Load Regulation
13 Temperature Coefficient
14 Over Current Protection
15 Over Voltage Protection
16 Hold-up Time (Typ)
17 Leakage Current
18 Remote Sensing
19 Parallel Operation
20 Series Operation
21 Operating Temperature
22 Operating Humidity
23 Storage Temperature
24 Storage Humidity
25 Cooling
26 Withstand Voltage
27 Isolation Resistance
28 Vibration
29 Shock (In package)
30 Safety
31 Line DIP
32 Conducted Emission
33 Radiated Emission
34 Immunity
35 Weight(Typ.)
36 Size (W x H x D)
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (Typ)
5 Input Voltage Range
6 Input Current (100/200VAC)(Typ) (*1)
7 Inrush Current(Typ)
8 PFHC
9 Output Voltage Range
ITEMS
to be described as 100 ~ 240VAC(50/60Hz).
For start up at low ambient temperature and low input voltage, output ripple noise might not meet specification.
However, there is no overshoot at start up and output ripple noise specification can be met after one second.
A225-01-01/A-B
=NOTES=
HWS30/A
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A225-01-02/A_).
(*1)
(*4)
MODEL
-10<Ta< 0°C
0<Ta<60°C
100VAC
200VAC
(*10) -
(*11) -
(*12) -
(*2) -
(*3) -
(*5) mV
(*6) mV
(*7) A
(*8) V
(*9) -
mm
mV
mV
W
%
%
V
A
A
V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SPECIFICATIONS
4.13~4.95
2.97~3.96
HWS30
0.6/0.3
Less than 0.5mA. 0.2mA(Typ) at 100VAC / 0.4mA(Typ) at 230VAC
-3/A
6.3 ~
120
160
3.3
20
70
73
20
40
6
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
More than 100M at 25°C and 70%RH Output - FG : 500VDC
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
-10 ~+60°C (-10 ~+40°C:100%,+50°C:60%,+60°C:20%)
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
6.25~7.25
HWS30
4.0~6.0
At no operating, 10 ~ 55Hz (Sweep for 1min)
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 370VDC
Built to meet SEMI-F47 (200VAC Line only)
31.5 x 82 x 95 ( Refer to Outline Drawing )
-5/A
6.3 ~
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
120
160
Output - FG : 500VAC (100mA) for 1min
30
77
80
20
40
6
5
19.6m/s
Built to meet UL508, DENAN
Built to meet IEC61000-3-2
30 ~ 90%RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
15.0~17.4
2
9.6~14.4
Less than 0.02% / °C
HWS30
Convection Cooling
Less than 196.1m/s
Constant, X,Y,Z 1hour each.
-12/A
2.62 ~
150
180
2.5
12
30
81
83
48
96
-30 ~ +85°C
Possible
20ms
260g
-
-
12.0~18.0
18.8~21.8
HWS30
0.8/0.4
-15/A
2.1 ~
150
180
120
15
30
81
83
60
2
2
DENSEI-LAMBDA
30.0~34.8
19.2~28.8
HWS30
-24/A
1.36 ~
31.2
200
240
192
1.3
24
83
86
96
38.4~52.8
55.2~64.8
HWS30
-48/A
0.68 ~
0.65
31.2
200
240
192
384
48
82
83