FPSS1U TDK Corporation, FPSS1U Datasheet - Page 31

RACK 3 SLOT FOR FPS1000

FPSS1U

Manufacturer Part Number
FPSS1U
Description
RACK 3 SLOT FOR FPS1000
Manufacturer
TDK Corporation
Series
FPSr
Datasheets

Specifications of FPSS1U

Accessory Type
Rack System
No. Of Slots
3
Peak Reflow Compatible (260 C)
No
External Width
19.00"
Rack U Height
1
External Depth
13.82"
For Use With
285-1239 - PWR SUP FNT END 48V 1008W 21A285-1238 - PWR SUP FNT END 32V 992W 31A285-1237 - PWR SUP FNT END 24V 960W 40A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
FPS1000 Series
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1240

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FPSS1U
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPSS1U/P
Manufacturer:
TDK-LAMBDA
Quantity:
232
10.7.5 Control and monitoring signals connector
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
9
CS
V_TRIM_C
SIGNAL_RETURN
DC_OK_C
+SENSE
AC_FAIL_B
ON/OFF_B
AC_FAIL_A
NC
NC
NC
SCL (I
SDA (I
-SENSE
TEMP_ALARM_C
AC_FAIL_C
ON/OFF_C
2
2
C)
C)
Open collector signal, referenced to pin 11 (Signal Return). On when the output voltage
of FPS1000 unit "C” is higher than ≥ 80%+/-5%. The maximum sink current: 10mA
and the maximum external voltage is 15V.
Positive sensing. The +Sense signal should be connected to the positive terminal of
the load. The +Sense and -Sense leads should be twisted pair to minimize noise pick-
up effect. The maximum load wires drop compensation is 1V/wire.
Open collector signal, referenced to pin 11 (Signal Return). On when the input voltage
of FPS1000 unit "B" is ≥85Vrms. The maximum sink current is 10mA, and the maximum
external voltage is 15Vdc.
Turns the output of FPS1000 unit "B" to On and Off by electrical signal or dry contact
between pin 15 and pin 11 (Signal Return). 0~0.6V or Short: On, 2~15V or Open:
Off. The maximum source current is 2.6mA.
Open collector signal, referenced to pin 11 (Signal Return). On when the input voltage
of FPS1000 unit "A" is ≥85Vrms. The maximum sink current is 10mA, and the maximum
external voltage is 15Vdc.
Not connected
Not connected
Not connected
Serial Clock used in the I
the Chapter 7 in this Instruction Manual.
Serial Data used in the I
the Chapter 7 in this Instruction Manual.
Negative sensing. The -Sense signal should be connected to the negative terminal
of the load. The -Sense and +Sense leads should be twisted pair to minimize noise
pick-up effect. The maximum load wires drop compensation is 1V/wire.
Open collector signal, referenced to pin 11 (Signal Return). On when the internal temperature
of FPS1000 unit "C" is within safe limit, Off approx 10°C below Thermal shut down. The
maximum sink current is 10mA and the maximum external voltage is 15V.
Open collector signal, referenced to pin 11 (Signal Return). On when the input voltage
of FPS1000 unit "C" is ≥85Vrms. The maximum sink current is 10mA, and the maximum
external voltage is 15Vdc.
Turns the output of FPS1000 unit "C" to On and Off by electrical signal or dry contact
between pin 25 and pin 11 (Signal Return). 0~0.6V or Short: On, 2~15V or Open: Off.
The maximum source current is 2.6mA.
Current sharing signal. When FPS-S1U racks are connected in parallel, the CS pins
of the units should be connected to allow current balance between units.
Connection for output voltage trimming of FPS1000 unit "C". The voltage can be
trimmed within its range specifications.
Return for the following control and supervisory signals: On/Off, DC_OK,
Over_temperature Alarm, AC_Fail, Auxiliary 12V supply. The Signal return is isolated
from the output terminals.
2
2
C interface option. Refer to the I
C interface option. Refer to the I
28
2
2
C interface description in
C interface description in

Related parts for FPSS1U