C8051T600SDB Silicon Laboratories Inc, C8051T600SDB Datasheet - Page 128

BOARD SOCKET DAUGHTER SOIC

C8051T600SDB

Manufacturer Part Number
C8051T600SDB
Description
BOARD SOCKET DAUGHTER SOIC
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051T600SDB

Module/board Type
Socket Module - SOIC
Data Bus Width
8 bit
Operating Supply Voltage
+ 1.8 V to + 3.6 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051T600DK
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1405
C8051T600/1/2/3/4/5/6
SFR Definition 23.2. SMB0CN: SMBus Control
SFR Address = 0xC0; Bit-Addressable
128
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
ARBLOST SMBus Arbitration Lost
TXMODE SMBus Transmit Mode
MASTER SMBus Master/Slave
ACKRQ
Name
MASTER
STO
ACK
STA
SI
R
7
0
Indicator. This read-only bit
indicates when the SMBus is
operating as a master.
Indicator. This read-only bit
indicates when the SMBus is
operating as a transmitter.
SMBus Start Flag.
SMBus Stop Flag.
SMBus Acknowledge
Request.
Indicator.
SMBus Acknowledge.
SMBus Interrupt Flag.
This bit is set by hardware
under the conditions listed in
Table 15.3. SI must be cleared
by software. While SI is set,
SCL is held low and the
SMBus is stalled.
TXMODE
R
6
0
Description
STA
R/W
5
0
STO
R/W
Rev. 1.2
4
0
0: SMBus operating in
slave mode.
1: SMBus operating in
master mode.
0: SMBus in Receiver
Mode.
1: SMBus in Transmitter
Mode.
0: No Start or repeated
Start detected.
1: Start or repeated Start
detected.
0: No Stop condition
detected.
1: Stop condition detected
(if in Slave Mode) or pend-
ing (if in Master Mode).
0: No Ack requested
1: ACK requested
0: No arbitration error.
1: Arbitration Lost
0: NACK received.
1: ACK received.
0: No interrupt pending
1: Interrupt Pending
ACKRQ
Read
R
3
0
ARBLOST
R
2
0
N/A
N/A
0: No Start generated.
1: When Configured as a
Master, initiates a START
or repeated START.
0: No STOP condition is
transmitted.
1: When configured as a
Master, causes a STOP
condition to be transmit-
ted after the next ACK
cycle.
Cleared by Hardware.
N/A
N/A
0: Send NACK
1: Send ACK
0: Clear interrupt, and initi-
ate next state machine
event.
1: Force interrupt.
ACK
R/W
1
0
Write
R/W
SI
0
0