C8051T600SDB Silicon Laboratories Inc, C8051T600SDB Datasheet - Page 151

BOARD SOCKET DAUGHTER SOIC

C8051T600SDB

Manufacturer Part Number
C8051T600SDB
Description
BOARD SOCKET DAUGHTER SOIC
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051T600SDB

Module/board Type
Socket Module - SOIC
Data Bus Width
8 bit
Operating Supply Voltage
+ 1.8 V to + 3.6 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051T600DK
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1405
SFR Definition 25.2. TCON: Timer Control
SFR Address = 0x88; Bit-Addressable
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
Name
TR1
TR0
TF1
TF0
IE1
IE0
IT1
IT0
R/W
TF1
7
0
Timer 1 Overflow Flag.
Set to 1 by hardware when Timer 1 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 1 interrupt service
routine.
Timer 1 Run Control.
Timer 1 is enabled by setting this bit to 1.
Timer 0 Overflow Flag.
Set to 1 by hardware when Timer 0 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 0 interrupt service
routine.
Timer 0 Run Control.
Timer 0 is enabled by setting this bit to 1.
External Interrupt 1.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 1 service routine in edge-triggered mode.
Interrupt 1 Type Select.
This bit selects whether the configured /INT1 interrupt will be edge or level sensitive.
/INT1 is configured active low or high by the IN1PL bit in the IT01CF register (see
SFR Definition 17.5).
0: /INT1 is level triggered.
1: /INT1 is edge triggered.
External Interrupt 0.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 0 service routine in edge-triggered mode.
Interrupt 0 Type Select.
This bit selects whether the configured INT0 interrupt will be edge or level sensitive.
INT0 is configured active low or high by the IN0PL bit in register IT01CF (see SFR
Definition 17.5).
0: INT0 is level triggered.
1: INT0 is edge triggered.
TR1
R/W
6
0
R/W
TF0
5
0
TR0
R/W
Rev. 1.2
4
0
Function
C8051T600/1/2/3/4/5/6
R/W
IE1
3
0
R/W
IT1
2
0
R/W
IE0
1
0
R/W
IT0
0
0
151