C8051T600SDB Silicon Laboratories Inc, C8051T600SDB Datasheet - Page 86

BOARD SOCKET DAUGHTER SOIC

C8051T600SDB

Manufacturer Part Number
C8051T600SDB
Description
BOARD SOCKET DAUGHTER SOIC
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051T600SDB

Module/board Type
Socket Module - SOIC
Data Bus Width
8 bit
Operating Supply Voltage
+ 1.8 V to + 3.6 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051T600DK
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1405
C8051T600/1/2/3/4/5/6
SFR Definition 17.4. EIP1: Extended Interrupt Priority 1
SFR Address = 0xF6
86
Name
Reset
7:6
Bit
Type
5
4
3
2
1
0
Bit
PWADC0 ADC0 Window Comparator Interrupt Priority Control.
Unused
PCP0R
PSMB0
PCP0F
PPCA0
PADC0
Name
R
7
1
Unused. Read = 11b; Write = Don’t Care.
Comparator0 (CP0) Rising Edge Interrupt Priority Control.
This bit sets the priority of the CP0 rising edge interrupt.
0: CP0 rising edge interrupt set to low priority level.
1: CP0 rising edge interrupt set to high priority level.
Comparator0 (CP0) Falling Edge Interrupt Priority Control.
This bit sets the priority of the CP0 falling edge interrupt.
0: CP0 falling edge interrupt set to low priority level.
1: CP0 falling edge interrupt set to high priority level.
Programmable Counter Array (PCA0) Interrupt Priority Control.
This bit sets the priority of the PCA0 interrupt.
0: PCA0 interrupt set to low priority level.
1: PCA0 interrupt set to high priority level.
ADC0 Conversion Complete Interrupt Priority Control.
This bit sets the priority of the ADC0 Conversion Complete interrupt.
0: ADC0 Conversion Complete interrupt set to low priority level.
1: ADC0 Conversion Complete interrupt set to high priority level.
This bit sets the priority of the ADC0 Window interrupt.
0: ADC0 Window interrupt set to low priority level.
1: ADC0 Window interrupt set to high priority level.
SMBus (SMB0) Interrupt Priority Control.
This bit sets the priority of the SMB0 interrupt.
0: SMB0 interrupt set to low priority level.
1: SMB0 interrupt set to high priority level.
R
6
1
PCP0R
R/W
5
0
PCP0F
R/W
Rev. 1.2
4
0
Function
PPCA0
R/W
3
0
PADC0
R/W
2
0
PWADC0
R/W
1
0
PSMB0
R/W
0
0

Related parts for C8051T600SDB