C8051T610DB28 Silicon Laboratories Inc, C8051T610DB28 Datasheet - Page 176

DAUGHTER BOARD T610 28QFN SOCKET

C8051T610DB28

Manufacturer Part Number
C8051T610DB28
Description
DAUGHTER BOARD T610 28QFN SOCKET
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051T610DB28

Module/board Type
Socket Module - QFN
Processor To Be Evaluated
C8051T61x
Interface Type
USB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051T610DK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
336-1506
C8051T610/1/2/3/4/5/6/7
SFR Definition 25.2. TCON: Timer Control
SFR Address = 0x88; Bit-Addressable
176
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
Name
TR1
TR0
TF1
TF0
IE1
IE0
IT1
IT0
R/W
TF1
7
0
Timer 1 Overflow Flag.
Set to 1 by hardware when Timer 1 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 1 interrupt service
routine.
Timer 1 Run Control.
Timer 1 is enabled by setting this bit to 1.
Timer 0 Overflow Flag.
Set to 1 by hardware when Timer 0 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 0 interrupt service
routine.
Timer 0 Run Control.
Timer 0 is enabled by setting this bit to 1.
External Interrupt 1.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 1 service routine in edge-triggered mode.
Interrupt 1 Type Select.
This bit selects whether the configured /INT1 interrupt will be edge or level sensitive.
/INT1 is configured active low or high by the IN1PL bit in the IT01CF register (see
SFR Definition 16.5).
0: /INT1 is level triggered.
1: /INT1 is edge triggered.
External Interrupt 0.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 0 service routine in edge-triggered mode.
Interrupt 0 Type Select.
This bit selects whether the configured INT0 interrupt will be edge or level sensitive.
INT0 is configured active low or high by the IN0PL bit in register IT01CF (see SFR
Definition 16.5).
0: INT0 is level triggered.
1: INT0 is edge triggered.
R/W
TR1
6
0
R/W
TF0
5
0
TR0
R/W
Rev 1.0
4
0
Function
R/W
IE1
3
0
R/W
IT1
2
0
R/W
IE0
1
0
R/W
IT0
0
0

Related parts for C8051T610DB28