Z8F08200100KIT Zilog, Z8F08200100KIT Datasheet - Page 149

no-image

Z8F08200100KIT

Manufacturer Part Number
Z8F08200100KIT
Description
DEV KIT FOR Z8 ENCORE 4K TO 8K
Manufacturer
Zilog
Series
Z8 Encore!®r
Type
MCUr
Datasheets

Specifications of Z8F08200100KIT

Contents
Evaluation Board, Cable, Power Supply, Software and Documentation
Data Bus Width
8 bit
Interface Type
RS-485
Silicon Manufacturer
Zilog
Core Architecture
Z8 Encore
Silicon Core Number
Z8F0822SJ020
Silicon Family Name
XP F0822
For Use With/related Products
Z8 Encore!™
For Use With
269-4661 - KIT ACC ETHERNET SMART CABLE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3183
PS022517-0508
Read Transaction with a 7-Bit Address
17. The I
18. If more bytes remain to be sent, return to
19. If the last byte is currently being sent, software sets the STOP bit of the I
20. The I
21. The slave can either Acknowledge or Not Acknowledge the last byte. Because either
22. The I
Figure 30
The shaded regions indicate data transferred from the I
unshaded regions indicate data transferred from the slaves to the I
Follow the steps below for a read operation to a 7-bit addressed slave:
1. Software writes the I
2. Software asserts the START bit of the I
3. If this is a single byte transfer, Software asserts the NAK bit of the I
4. The I
5. The I
6. If the I
S
I
Software responds to the Not Acknowledge interrupt by setting the STOP and FLUSH
bits and clearing the TXI bit. The I2C Controller sends the STOP condition on the bus
and clears the STOP and NCKI bits. The transaction is complete (ignore the following
steps).
Transmit Interrupt is asserted.
Register (or START bit to initiate a new transaction). In the STOP case, software also
clears the TXI bit of the I
the STOP or START bit is already set, the NCKI interrupt does not occur.
the STOP (or START) bit.
so that after the first byte of data has been read by the I
Acknowledge is sent to the I
next high period of SCL, the I
Continue with
2
C Controller sets the NCKI bit and clears the ACK bit in the I
Figure 30. Receive Data Transfer Format for a 7-Bit Addressed Slave
2
2
2
2
2
C Controller sends the STOP (or RESTART) condition to the I
displays the data transfer format for a read operation to a 7-bit addressed slave.
C Controller shifts the data out by the SDA signal. After the first bit is sent, the
C Controller completes transmission of the last data byte on the SDA signal.
C Controller sends the START condition.
C Controller shifts the address and read bit out the SDA signal.
2
Slave Address
C Slave acknowledges the address by pulling the SDA signal Low during the
step
7.
2
C Data Register with a 7-bit Slave address plus the read bit (=1).
2
C Control Register at the same time.
2
C Slave.
2
C Controller sets the ACK bit in the I
R = 1
2
C Control Register.
step
A
14.
Data
2
Z8 Encore! XP
C Controller to slaves and
2
C Controller, a Not
A
Product Specification
2
C Controller.
2
C Status register.
Data
2
C Control Register
2
2
®
C Status register.
C bus and clears
F0822 Series
2
I2C Controller
C Control
A
P/S
136