EPSILON5-UPG3 Equinox Technologies, EPSILON5-UPG3 Datasheet

UPGRADE EPSILON5 JTAG ISP AVRMCU

EPSILON5-UPG3

Manufacturer Part Number
EPSILON5-UPG3
Description
UPGRADE EPSILON5 JTAG ISP AVRMCU
Manufacturer
Equinox Technologies
Type
Upgrade Kitr
Datasheet

Specifications of EPSILON5-UPG3

Mfg Application Notes
SPI and JTAG (ISP), Appl Note
For Use With/related Products
Epsilon5
Other names
483-1008
Portable ISP Programmer for
Atmel, Atmel Wireless (Temic) and
Philips FLASH Microcontrollers
User Guide

Related parts for EPSILON5-UPG3

EPSILON5-UPG3 Summary of contents

Page 1

Portable ISP Programmer for Atmel, Atmel Wireless (Temic) and Philips FLASH Microcontrollers User Guide ...

Page 2

... Steps required before operating the programmer in Standalone Mode ..............33 2.6.3 How to export your Development (EDS) project to Project Builder .....................33 2.6.4 Executing a Programming Project in Standalone Mode ......................................34 2.7 Script Mode...................................................................................................................35 2.8 ConsoleEDS – Command Line control.........................................................................35 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 i ...

Page 3

... J6(b) - Equinox 10-way Header (ATtiny11/12/15 HV Interface) ...................................66 4.7 J6(c) - Equinox 10-way Header (UART Boot Loader) ..................................................68 4 Atmel 10-way Header (SPI Interface) ....................................................................70 4 Atmel 10-way JTAG Header (JTAG Interface) ......................................................72 4.10 ISP Cable considerations............................................................................................74 ii EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 4

... Equinox guarantees that its products will be free from defects of material and workmanship under normal use and service, and these products will perform to current specifications in accordance with, and subject to, the Company’s standard warranty which is detailed in Equinox’s Purchase Order Acknowledgment. EPSILON5 MKII Programmer - User Guide V1.12 – ...

Page 5

... ISP Cable into a Target System. Warning! Any damage caused to the programmer by Electrostatic Discharge (ESD) through inadequate earthing is not covered under the warranty of the product. iv EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 6

... This type of problem is usually listed in the ‘Errata Sheet’ for the particular device being programmed and is available from the silicon vendor. Information contained in this manual is for guidance purposes only and is subject to change. E&OE. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 7

... Electromagnetic Compatibility (EMC) Compliance The ‘EPSILON5’ Approved Product designed for use in an ESD controlled environment i.e. development or production. This means, therefore, that the user must ensure that there is no possibility of damage from electrostatic discharge (ESD). Since the devices and equipment to which this product is likely to be connected may well themselves be susceptible to ESD, this should not pose any difficulty ...

Page 8

... Equinox will try our best to answer your questions about this product as quickly as possible. However, we cannot promise an immediate reply. Please consult our web site for new software updates as the problem that you are enquiring about may have already been fixed in a new version. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 vii ...

Page 9

... Product Documentation This manual provides an overview of the contents of the EPSILON5 Programming System plus associated hardware and software. References may be made to other hardware and software products which are not covered in detail in this manual. Please refer to the table below for a list of sources of documentation and/or browse to: http://www ...

Page 10

... The following sources of documentation are available for this software: • • • EPSILON5 MKII Programmer - User Guide V1.12 – 1 Installation and User Manual Help File Configit – Firmware Upgrade Utility This utility is used to upgrade the firmware of the programmer. A firmware update may be required to add support for new devices and to correct any firmware issues ...

Page 11

... Browse to http://www.equinox-tech.com • Click / select the <Downloads> tab • Type in the name of the programmer e.g. EPSILON5 into the ‘Product Name’ field • Click the <Search> button a list of all the software and documentation available for this product are displayed. • ...

Page 12

... Programmer Overview 1.1 System Contents EPSILON5 MKII Programmer - User Guide V1.12 – 1 Hardware • EPSILON5 MKII Programmer • Jumper Links for internal jumpers Cables • DC Power Cable • 9-way Female to 9-way Male Serial Cable • 25-way Female to 9-way Male Serial Adaptor • ...

Page 13

... Status LED’s: <PASS> LED <BUSY> LED <FAIL> LED <NO> Button - Used to cancel a programming operation. <YES> Button - Used to start an ‘autoprogram’ operation. Bottom Panel 1. RS-232 port (J5) 2. External DC Power Supply Input (CON1) EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 14

... Hardware Overview (internal layout) EPSILON5 MKII Programmer - User Guide V1.12 – 1 Hardware 1. Atmel 6-way ISP (SPI) Header 2. Equinox 10-way ISP (SPI / UART) Header 3. Atmel 10-way ISP (SPI) Header 4. Jumper (J9) – Vcc Link 5. Jumper (J10) – Enable Target Power LED 6. Status LED’s 7 ...

Page 15

... To return to the ‘Standby’ state The <YES> button has the following functions execute a programming project which has been pre-loaded into the programmer ‘FLASH Memory Store’. ii. To return to the ‘Standby’ state EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 16

... Target Vcc Voltage Detection • LED EPSILON5 MKII Programmer - User Guide V1.12 – 1 Atmel Low Voltage SPI Atmel High Voltage SPI (+12V Vpp) Atmel AVR JTAG (chargeable update) Atmel (formerly Temic) 8051 Boot loader ISP Development Mode (PC controlled) Project Upload Mode using Upload Wizard (PC ...

Page 17

... SLOW SPI: 0 – 490.2 kHz (user selectable) MEDIUM SPI: 0 – 490.2 kHz (user selectable) SLOW SPI: 115.2 kHz to 921.6 kHz (user selectable) FAST SPI: 115.2 kHz to 921.6 kHz (user selectable) EPSILON5 MKII Programmer - User Guide V1.12 – 1 2.3 3.0 1.5.2 1.5.2 1 ...

Page 18

... Temperature range deg Size (enclosure) 189H x 80L x 31D mm 24 Shipped Weight 0.75 kg EPSILON5 MKII Programmer - User Guide V1.12 – 1 Atmel 10-way (SPI) Atmel 6-way (SPI) Atmel 10-way (JTAG) Equinox 10-way (SPI+UART) RS232 9-way Female D Connector Connects to spare PC COM port All 9 connections must be made in serial cable. ...

Page 19

... For most Atmel AVR and AT89S devices, the FLASH and EEPROM Write Times increase as the Target Voltage decreases. The timings are automatically set for you in your project as long as you have declared the correct Target Vcc voltage in your project. 8 EPSILON5 MKII Programmer - User Guide V1.12 – 1 Min Max Units ...

Page 20

... Standby Mode – All LED’s OFF (Target Vcc is OFF so the Target Vcc LED is also OFF) 1.5.3.2 Maximum Current handling of programmer If the programmer is supplying power to the Target System, then the current drawn by the Target System must be below the maximum value stated in the table below. EPSILON5 MKII Programmer - User Guide V1.12 – 1 CON1 Vcc (V) Min Typ 5 ...

Page 21

... The external voltage applied to CON1 must be between 3.1 and 5. Comments • Power is supplied from External Power Supply via CON1 • fitted connecting the CON1 Vcc to the Target Vcc EPSILON5 MKII Programmer - User Guide V1.12 – 1 Typ Max Units - 300 mA st August 2007 ...

Page 22

... J5 – RS-232 Communications Port & Serial Cables 1.5.6.1 Connecting the programmer to the PC COM port The EPSILON5 programmer communicates with a PC via the RS-232 Communications Port (J5). A suitable 9-way to 9-way serial cable is supplied with the programmer. The programmer is supplied with the following PC Serial Cables / Adaptors: 1 ...

Page 23

... CTS Not Connected 9 RING Not Connected Fig. 1.5.6.2 Connections for 9-way to 9-way Serial Cable (Straight through cable) 9-way (Male) 9-way (Female Fig. 1.5.6.3 Connections for 9-way to 25-way Adaptor 25-way (Female) 9-way (Male EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 24

... EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 13 ...

Page 25

... UART Boot T89C51 RB2 / RC2 / RD2 Loader T89C51 IB2 / IC2 T89C51CC01 (Support for the AT89Cxxxx devices is not currently available) UART Boot P89C51 RB2 / RC2 / RD2 Loader P89C 660 / 662 / 664 / 668 LV SPI ZW0102 / ZW0201 / ZW0301 EPSILON5 MKII Programmer - User Guide V1.12 – ...

Page 26

... AVR) AT90USB AT90CAN Please refer to section 4 for information on which ISP Header to use for the required programming interface. EPSILON5 MKII Programmer - User Guide V1.12 – 1 Description / Comment Atmel Low Voltage Serial Programming Mode • Atmel 3-wire SPI interface (SCK, MOSI, MISO ) • ...

Page 27

... EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 28

... Getting Started Guide EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 17 ...

Page 29

... ConsoleEDS Further help and instructions can be found in the ‘EQTools – Getting Started Guide’ (pdf manual) and also in the ‘EQTools – On-line Help File’ (Press <F1> within EQTools). 18 EPSILON5 MKII Programmer - User Guide V1.12 – 1 Refer to section 2.2 2.3 2.4 2 ...

Page 30

... Please refer to section 3 for a full explanation of which is the correct way of powering the programmer for your application. 6 Check J5 – Firmware Update Jumper - is NOT fitted EPSILON5 MKII Programmer - User Guide V1.12 – 1 Observation You will need the following items: • Epsilon5 programmer • ...

Page 31

... Programmer circuitry powers up to 3.0V. If the Jumper Link J9 is fitted then the ‘Target Vcc’ LED will illuminate. All LED’s go out The ISP Cable should fit through the slot in the end panel. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 32

... Electrostatic Discharge (ESD) Warning! There are a number of electrostatic issues which must be taken into account to avoid damage to the programmer and/or the Target System during In-System Programming. Please see section 3.3. EPSILON5 MKII Programmer - User Guide V1.12 – 1 Target Vcc LED illuminates st August 2007 ...

Page 33

... Certain options such as compiling and running of ‘Programming Scripts’ must be purchased from Equinox as a ‘License upgrade. The table below details the various EQTools components and whether they are enabled as standard. Fig. 2.3.1 Software / Control Options for the Epsilon5 Programmer EQTools - Project Builder EQTools - Project Management Utility ...

Page 34

... ConsoleEDS This is a powerful utility which allows any Equinox ISP Programmer to be controlled from a PC application by executing simple command line instructions. This method of control is ideal for interfacing the programmer to any Windows application. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 23 ...

Page 35

... Software Installation The Epsilon5 programmer comes with the software suite called EQTools as standard. The latest version of this software which was available at the time of shipping is supplied on CD-ROM with the programmer. However, this software version is likely to have been superseded by a newer version. ...

Page 36

... Operating the programmer The EPSILON5 programmer can be used in the following Operating Modes as detailed in the table below: # Programmer Connect Control Method Mode Software COM Port 1 Development Yes EQTools - EDS Mode 2 Standalone No None Mode 3 Script Mode Yes EQTools – Script Debugger or ISP-PRO ...

Page 37

... Communications 26 Upgrade In this mode, the programmer Required is controlled via a simple ASCII Protocol. A simple Terminal Emulator is required to test out this mode or the ASCII commands can be generated by an external controller. EPSILON5 MKII Programmer - User Guide V1.12 – 1 See App Note AN110 st August 2007 ...

Page 38

... Select FLASH Data File (optional – you can enter the file name at a later stage in EDS) • Select EEPROM Data File (optional – you can enter the file name at a later stage in EDS) EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 39

... Click the <Test Project in EDS> button at the bottom right of the Project Manager window • The EDS window now launches with all the settings of the select Programming Project – see section 2.5.4 28 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 40

... FLASH Area Programming, EEPROM Area programming, Configuration Fuse Programming and Security Fuse programming also possible to set up the SPI / JTAG / UART Target Speeds and the Power Supply Settings from EDS. Fig. 2.5.4.1 EDS – FLASH Tab Overview EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 29 ...

Page 41

... The bytes are grouped into rows of 16 bytes with the start address of each row displayed in the left-hand column. The Hexadecimal representation of the 16 bytes is displayed in the middle column The ASCII representation of the 16 bytes is displayed in the right- hand column. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 42

... Calc CRC EPSILON5 MKII Programmer - User Guide V1.12 – 1 Re-loads the specified HEX / Binary file into the Buffer Window. Tick the box to enable manual editing of the Buffer Window. This will also allow the <Load>, <Erase> and <Fill> buttons to be selected ...

Page 43

... Click the <Security> tab to read / write the Target Chip ‘Security Options’ For further instructions about how to use the EDS utility, please refer to the ‘EQTools – Getting Started Guide’ which can be found on the CD-ROM supplied with the programmer. 32 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 44

... Save the Project Collection with a suitable name eg. Myprojects.ppc • Click the <Upload> icon on the icon bar to upload the Project Collection to the programmer. the <Upload Wizard> utility will launch • Follow the on-screen instructions to upload the Project Collection to the programmer. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 33 ...

Page 45

... Mode’ differ depending on how the programmer and Target System are powered. Jumper J9 Voltage ( FITTED 3.1 – 5.0 FITTED 3.1 – 5.0 NOT FITTED 3.1 – 5.0 EPSILON5 MKII Programmer - User Guide V1.12 – 1 Refer to section 3.2 3.3 3.4 3.5 3.6 st August 2007 ...

Page 46

... Supports reading / writing of Atmel AVR on-chip Oscillator Calibration Byte Please note: Many of the above features are only accessible when using ‘ConsoleEDS PRO’. Typical ConsoleEDS example: ConsoleEDS BaseProject.prj /AUTOPROGRAM=MainFirmware /EEPROMWRITE=CalData.hex,0,50 For further information about ConsoleEDS, please refer to Application Note 111. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 35 ...

Page 47

... EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 48

... Programming Instructions 3.1 Overview The EPSILON5 programmer has been designed so that it can be powered both directly from a Target System (3.1 – 5.0V) and also from an external power supply (3.1 – 5.0V). This makes the programmer ideal for both standalone use (not connected to a PC) and development use (connected to a PC) ...

Page 49

... Target Vcc and GROUND within the Test Fixture. This diode would help to prevent damage to the programmer due to the Target Vcc being > 5V Jumper (J9) – Vcc Jumper Fitted – CON1 V_EXT_PSU is connected to TARGET_VCC Not Fitted – Programmer PSU is independent of Target Vcc 38 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 50

... Fig 3.2.2 – Programmer / Target System Power Supply Overview Schematic Please refer to fig 3.2.1 for an explanation of all circuit diagram labels etc. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 39 ...

Page 51

... Target System ! The solution: • Ensure that the PC chassis is properly earthed to mains earth. • Connect an earthing bond wire from the PC chassis to the GROUND connection of either the programmer or the Target system / Test Fixture. 40 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 52

... Please ensure that any devices connected to the user target system are also properly grounded to the same common earth point Warning! Any damage caused to the programmer by Electrostatic Discharge (ESD) through inadequate earthing is not covered under the warranty of the product. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 41 ...

Page 53

... The all black lead is the GROUND cable. • The external voltage applied to CON1 must be between 3.1 and 5.0V ! • The Target System must not draw more than 300 mA from the programmer. 42 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 54

... Circuit Schematic - Programmer powers the Target System Please refer to fig 3.2.1 for an explanation of all circuit diagram labels etc. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 43 ...

Page 55

... V_TVCC = V_EXT_PSU FAIL LED starts flashing. Pressing any button will have no effect. programmer is now in ‘Autoprogram Mode’. Press the <YES> button again to execute the Programming Project. All LED’s go out EPSILON5 MKII Programmer - User Guide V1.12 – 1 Status of LED’s st August 2007 ...

Page 56

... Replace programmer lid and tighten screws EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 45 ...

Page 57

... Programmer starts an ‘Autoprogram’ operation Programmer OUTPUT lines will now be driven high/low by the programmer for the duration of the programming operation. BUSY LED remains on throughout the ‘Autoprogram’ operation button EPSILON5 MKII Programmer - User Guide V1.12 – 1 Status of LED’s st August 2007 ...

Page 58

... Programming operation has PASSED. 7b. To program a new Target System: i. Press the once ii step 3 EPSILON5 MKII Programmer - User Guide V1.12 – 1 FAIL LED flashes Programmer tri-states all outputs connected to the Target System FAIL LED goes out Programmer is in ‘Standby’ mode again < ...

Page 59

... The Target System must be able to supply the worst case current required during a programming operation – see section 1.5.3. • A 6V2 5W zener diode is internally connected across the programmer supply to protect against over-voltage. 48 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 60

... Circuit Schematic - Target System powers the Programmer Please refer to fig 3.2.1 for an explanation of all circuit diagram labels etc. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 49 ...

Page 61

... Vcc Voltage FAIL LED starts flashing. Pressing any button will have no effect. programmer is now in ‘Autoprogram Mode’. Press the <YES> button again to execute the Programming Project. All LED’s go out EPSILON5 MKII Programmer - User Guide V1.12 – 1 Status of LED’s st August 2007 ...

Page 62

... LED flashing – step 8a. iv. <FAIL> LED FLASHING – step 7a. To cancel a programming operation part-way- through press the EPSILON5 MKII Programmer - User Guide V1.12 – 1 Observation All LED’s are OFF No change as Target power supply is OFF. Target System powers up Programmer circuitry powers ...

Page 63

... LED flashes Programmer tri-states all outputs to connect to Target system Target System RESET is released (target code may start to execute) Target System powers down All LED’s go OFF Programmer powers OFF No change EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 64

... The voltage applied to the programmer via the ISP cable must be between 3.1 and 5.0V as this voltage is used to drive the programmer I/O Stage. A 6V2 5W zener diode is internally connected across the programmer supply to protect against over-voltage. • J9 must be removed to avoid contention between the two power supplies. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 53 ...

Page 65

... Circuit Schematic - Programmer and Target System independently powered Please refer to fig 3.2.1 for an explanation of all circuit diagram labels etc. 54 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 66

... Project before using the programmer in Standalone Mode. 7c There is a valid Programming Project in the Programmer. 8 Remove power from programmer EPSILON5 MKII Programmer - User Guide V1.12 – 1 Observation This disconnects the Programmer Vcc (from Con1) to the Target Vcc. All LED’s are OFF Programmer and Target system are NOT powered. All LED’ ...

Page 67

... Replace programmer lid and tighten screws 3.6.5 Programming Instructions As the programmer is always powered ON, the programming instructions are exactly the same as for when the programmer powers the Target System except that jumper J9 must be removed. Please refer to section 3.4.5. 56 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 68

... ISP Header Selection 4.1 Overview The EPSILON5 programmer caters for many different connection methods to a Target System by featuring FOUR possible ISP Header connectors. Each header provides the necessary signals to program the Target Device plus Vcc (power) and GND (Ground). The choice of which header to use depends on the ‘ ...

Page 69

... ISP Header Selection Chart (by header) The FOUR ISP Headers featured on the EPSILON5 are detailed in the table below. Please refer to the section indicated in the ‘refer to section’ column for specific details of each header. # ISP Description / Function Header 1 J3 Atmel 6-way ISP Header Header J6 can have THREE different pin-outs depending on which Target Device programmed ...

Page 70

... J8 Atmel 10-way JTAG Header Device support: Atmel ATmega32/128 + any new devices with JTAG port EPSILON5 MKII Programmer - User Guide V1.12 – 1 4.9 st August 2007 59 ...

Page 71

... LV SPI ATtiny11/12/15L HV SPI T89CRB2/RC2/RD2 UART Boot Loader P89CRB2/RC2/RD2 UART Boot Loader P89C662/4/8 UART Boot Loader ZW0102, ZW0201 LV SPI EPSILON5 MKII Programmer - User Guide V1.12 – 1 App Note J6(a) 4.4, 4.5 AN103 J7 4.8 J6(a) 4.4, 4.5 AN100 J7 4.8 J6(a) 4.4, 4.5 AN101 J7 4 ...

Page 72

... SCK2 Oscillator so it should only be used if this functionality is not required. To implement this connection method, simply plug a 6-way ISP cable (not supplied) into the EPSILON5 ISP Header J3 and plug the other end of the cable into the matching header on the Target System. Pin ...

Page 73

... This pin controls the Target Device RESET pin. It will driven HIGH/LOW according to the device type and settings in the ‘Pre-program State Machine’ tab in the Eqtools project. GROUND Ground Connection Common ground connection between PROGRAMMER and Target System. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 74

... Spare I/O pin which could be used for SPI SLAVE SELECT or to drive an LED on the Target System To implement this connection, simply plug the 10-way ISP cable into the EPSILON5 J6 header and plug the other end of the cable into the matching header on the Target System. ...

Page 75

... State Machine> tab in the Eqtools project. Warning! During ‘High Voltage Serial Programming’ of the Atmel ATtiny11/12/15 microcontrollers, a +12V Vpp voltage is generated by the programmer on this pin. EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Page 76

... Key O - Output from programmer to Target Device I - Input to programmer from Target Device P - Passive eg. GROUND and power rails N/C - Not connected EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 65 ...

Page 77

... Serial Programming Mode’. This mode requires that a +12.0V Vpp voltage is applied to the RESET pin of the target device in order to enter programming mode. To implement this connection, simply plug the 10-way ISP cable into the EPSILON5 J6 header and plug the other end of the cable into the matching header on the Target System. Please ensure that you have made the correct connections from the ISP Header to your Target Device ...

Page 78

... O - Output from programmer to Target Device I - Input to programmer from Target Device P - Passive eg. GROUND and power rails N/C - Not connected EPSILON5 MKII Programmer - User Guide V1.12 – 1 This is the serial data output pin from the programmer. This pin should be connected to the Serial Data Input (SDI) pin on the Target Microcontroller ...

Page 79

... A Philips P89C51Rx2 or P89C66x microcontroller • The relevant connections for in-system programming via the Boot Loader. To implement this connection, simply plug the 10-way ISP cable into the EPSILON5 J6 header and plug the other end of the cable into the matching header on the Target System. Please note: The programmer interfaces to the Target System at TTL voltage levels ...

Page 80

... O Key O - Output from programmer to Target Device I - Input to programmer from Target Device P - Passive eg. GROUND and power rails N/C - Not connected EPSILON5 MKII Programmer - User Guide V1.12 – 1 N/C Not Connected TXD Programmer RXD (Transmit) pin The programmer receives serial data on this pin from the Target Device TXD (Transmit) pin ...

Page 81

... Header’ as the Equinox header caters for an External Oscillator, Vpp switching and also features a spare I/O pin for future expandability. To implement this connection, simply plug the 10-way ISP cable into the EPSILON5 ISP Header J7 and plug the other end of the cable into the matching header on the Target System. ...

Page 82

... O - Output from programmer to Target Device I - Input to programmer from Target Device P - Passive eg. GROUND and power rails N/C - Not connected EPSILON5 MKII Programmer - User Guide V1.12 – 1 RESET Target RESET control pin This pin controls the Target Device RESET pin. It will driven HIGH/LOW according to the device type and settings in the ‘ ...

Page 83

... Atmel 10-way IDC JTAG Header • This is the same header as used on the Atmel JTAG-ICE emulator. To implement this connection, simply plug the 10-way ISP cable into the EPSILON5 ISP Header J8 and plug the other end of the cable into the matching header on the Target System. Pin ...

Page 84

... P Key O - Output from programmer to Target Device I - Input to programmer from Target Device P - Passive eg. GROUND and power rails N/C - Not connected EPSILON5 MKII Programmer - User Guide V1.12 – 1 TARGET_VCC Target Vcc Connection - See pin 4 - Pins are physically connected inside the programmer. N/C Not Connected TDI JTAG TDI – ...

Page 85

... If you are using the programmer in a production environment and constantly plugging / unplugging the ISP cable into/from the Target System, you may find that the cable eventually fails. Spare ISP cables can be ordered from Equinox in this eventuality. 74 EPSILON5 MKII Programmer - User Guide V1.12 – August 2007 ...

Related keywords