JM1AN-TMP-DC48V-F Panasonic Electric Works, JM1AN-TMP-DC48V-F Datasheet
JM1AN-TMP-DC48V-F
Specifications of JM1AN-TMP-DC48V-F
Related parts for JM1AN-TMP-DC48V-F
JM1AN-TMP-DC48V-F Summary of contents
Page 1
... FASTON placement/removal. • Flux resistance mechanism The terminal area is plugged with resin to prevent flux seepage during PCB mounting. (TMP type) F All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. VDE JM RELAYS • Conforms to the various safety standards UL, CSA, VDE available • The line up can support economical mounting methods ...
Page 2
... Inrush 80 A, Cut-off 80 A (When the motor is locked) (250 V AC cos = 0.7) / HP, 20A 125VAC 1 2 TMP type (Slim) JM1aN-TMP-DC5V-F JM1aN-P-DC5V-F JM1aN-TMP-DC6V-F JM1aN-P-DC6V-F JM1aN-TMP-DC9V-F JM1aN-P-DC9V-F JM1aN-TMP-DC12V-F JM1aN-P-DC12V-F JM1aN-TMP-DC24V-F JM1aN-P-DC24V-F JM1aN-TMP-DC48V-F JM1aN-P-DC48V-F Coil resistance Nominal operating [ 10%] ( power 27 900mW 160 640 2,560 Specifications 140 F) – ...
Page 3
... General tolerance: 0.4 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 3. Operate/release time Sample: JM1aN-TMP-DC24V-F, 5 pcs Release time 100 110 120 130 Coil applied voltage, %V mark can be downloaded from: http://panasonic-electric-works ...
Page 4
... AC E43028 20A 125V AC 20A 250V AC Flat type 125V AC 2 1HP 250V AC For Cautions for Use. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. External dimensions 47.5 1.870 31 1.220 10 .394 R2.25 N.O. R.088 Faston 250 Faston 187 39.5 1 ...