T92S11D12-24 Tyco Electronics, T92S11D12-24 Datasheet

RELAY PWR PC MNT DPDT 30A 24VDC

T92S11D12-24

Manufacturer Part Number
T92S11D12-24
Description
RELAY PWR PC MNT DPDT 30A 24VDC
Manufacturer
Tyco Electronics
Series
T92r
Datasheets

Specifications of T92S11D12-24

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
30A
Switching Voltage
240VAC
Coil Type
Standard
Coil Current
70.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
30A @ 240VAC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
2.4 VDC
Coil Voltage Vdc Nom
24V
Contact Current Max
30A
Contact Voltage Ac Nom
600V
Contact Voltage Dc Nom
28V
Coil Resistance
350ohm
Contact Configuration
DPDT
Contact Rating
30 A at 24 VDC
Contact Termination
PCB
Mounting Style
Panel
Power Consumption
1.7 W
Contact Material
Silver Cadmium Oxide
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
9-1393211-0
PB352

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T92S11D12-24
Manufacturer:
TYCO
Quantity:
10 000
Part Number:
T92S11D12-24-24V
Quantity:
5 400
Part Number:
T92S11D12-24V
Manufacturer:
Potter&Brumfieid
Quantity:
5 400
Dimensions are shown for refer-
ence purposes only.
Contact Ratings @ 25°C with relay properly vented.
Remove tape over vent hole after soldering and cleaning.
Arrangements: 2 Form A (DPST-NO) and 2 Form C (DPDT).
Materials: Silver cadmium oxide and silver tin indium oxide.
Max. Load Rating, Silver Cadmium Oxide Contacts:
Max. Load Rating, Silver Tin Indium Oxide Contacts
Min. Load Rating:
Expected Mechanical Life: 5 million operations.
Expected Electrical Life: 100,000 operations at rated load, except as
Features
• 30A DPST-NO and DPDT switching capabilities.
• Designed to control compressor loads to 3.5 tons, 25.3 FLA, 110 LRA.
• Extended life – >300,000 operations at 30A, 240VAC (DC coil).
• Meets requirements of UL873 and UL508 spacings.
• Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-contacts.
• Meets requirements of UL Class F construction.
• UL approved for 600VAC switching (1.5HP).
• Conforms to VDE 0435, 0631, and 0700.
• New screw terminal version.
Normally Open Contacts:
Normally Closed Contacts:
Normally Open Contacts Only:
Normally Open Contacts: 500mA @ 12VAC/VDC.
Normally Closed Contacts: 100mA @ 6VAC/VDC.
– .315” (8mm) through air, .375” (9.5mm) over surface.
40A @ 277VAC, resistive; 6K Ops. (Flange Mount);
30A @ 120/277VAC, resistive;
10A @ 600VAC, resistive;
1 HP @ 120VAC, 3 HP @ 240VAC;1.5 HP @ 480VAC, 1.5 HP @ 600VAC
110 LRA, 25.3 FLA, @ 240VAC with DC coil
60 LRA, 14 FLA @ 240VAC with AC coil;
3A @ 240VAC pilot duty;
20A @ 28VDC;
TV10 @ 120VAC.
VDE Rating (Flange Mount): 20A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
VDE Rating (PC Mount): 30A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
3A @ 28VDC or 277VAC, 2A @ 480VAC, 1A @ 600VAC.
VDE Rating (Flange or PC Mount): 3A @ 400VAC, 30K Ops.
30A @ 120/277VAC, resistive; 200K Ops., DC Coil; 100K Ops, AC Coil
20A @ 480VAC, resistive;
1.5 HP @ 120VAC, 2 poles making/breaking (see Fig. 1)
3 HP @ 240VAC, 3 phase, DC coil only;
3 HP @ 480VAC, 3 phase, DC coil only;
2 HP @ 600VAC, 3 phase, DC coil only.
>100,000 operations at 30A, 240VAC (AC coil).
specifically noted otherwise.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
(1)
;
Issued 3-03 (PDF Rev. 8-07)
Catalog 1308242
T92
Two-Pole, 30 Amp
PC Board or Panel Mount Relay
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files
of the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Coil Data
Voltage: 12 through 110VDC and 12 through 277VAC.
Resistance: See Coil Data table.
Nom. Power: AC Coil: 4.0VA; DC Coil: 1.7W.
Coil Temp. Rise: 35°C/W.
Max. Coil Temp.: 155°C.
Duty Cycle: Continuous.
Coil Data (@ 25°C Coil Temperature)
Contact Ratings (continued)
ARI 780-86 Endurance Test (section 6.6):
Notes: Vent hole tape must be removed to achieve all listed ratings.
Initial Dielectric Strength
Between Contacts and Coil: 4,000V rms, 50/60 Hz.
Between Open Contacts: 1,500V rms, 50/60 Hz.
Between Poles: 2,000V rms, 50/60 Hz.
Initial Insulation Resistance
Between Mutually Insulated Elements: 10
Notes
(1) FLA, LRA ratings are compatible with 3.5 ton compressor applications.
(2) Nominal voltage, no coil suppression, excluding bounce.
Nom. Voltage
HVAC Definite Purpose Contactor Standard
Normally Open Contacts
Nom. Voltage
Single Phase/Two Pole (Both poles together switching a single load)
Figure 1
Single Phase Per Pole (Single load per pole)
Figure 2
File E22575
File LR15734
110 LRA, 25.3 FLA, 200K operations (DC Coil)
110 LRA, 18 FLA, 200K operations (DC Coil).
60 LRA, 14 FLA, 200K operations (AC Coil).
( VAC )
( VDC )
Specifications and availability
subject to change.
24
12
24
12
series
T1
Freq.
60
60
L1
±10% ( Ohms )
L1
DC Resist.
T1
±10% ( Ohms )
350
DC Resist.
86
36.6
L2
9.1
AC Coils ( 4.0VA )
DC Coils ( 1.7W )
L2
T2
T2
File E22575 (type 2,3,4,5)
File No. 5386 (type 1,2,3,4)
Nom. Voltage
Nom. Voltage
200/208
220/240
250/277
110/120
( VAC )
9
( VDC )
110
48
ohms, min. @ 500VDC.
50/60
50/60
50/60
50/60
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Freq.
±10% ( Ohms )
DC Resist.
±10% ( Ohms )
DC Resist.
1,390
7 ,255
3,800
5,485
2,841
950
P&B
511

Related parts for T92S11D12-24

T92S11D12-24 Summary of contents

Page 1

Features • 30A DPST-NO and DPDT switching capabilities. • Designed to control compressor loads to 3.5 tons, 25.3 FLA, 110 LRA. • Extended life – >300,000 operations at 30A, 240VAC (DC coil). >100,000 operations at 30A, 240VAC (AC coil). • ...

Page 2

Ambient Temperature vs. Coil Voltage 120 100 100 105 110 115 120 125 130 135 140 145 150 Applied Coil Voltage (% of Rated Nominal) Assumptions: 1. Thermal resistance ...

Page 3

Outline Dimensions Mounting & Termination Type 1 2.06 MAX. (52.32) 1.21 MAX. (30.73) .156 (3.96) 1.618 ± .020 (41.10 ± .51) .585 ± .005 (14.86 ± .13) .032 TYP. .309 ± .005 (0.81) (7.85 ± .13) 1.000 ± .010 .630 ...

Related keywords