T92S11D12-24 Tyco Electronics, T92S11D12-24 Datasheet

RELAY PWR PC MNT DPDT 30A 24VDC

T92S11D12-24

Manufacturer Part Number
T92S11D12-24
Description
RELAY PWR PC MNT DPDT 30A 24VDC
Manufacturer
Tyco Electronics
Series
T92r
Datasheets

Specifications of T92S11D12-24

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
30A
Switching Voltage
240VAC
Coil Type
Standard
Coil Current
70.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
30A @ 240VAC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
2.4 VDC
Coil Voltage Vdc Nom
24V
Contact Current Max
30A
Contact Voltage Ac Nom
600V
Contact Voltage Dc Nom
28V
Coil Resistance
350ohm
Contact Configuration
DPDT
Contact Rating
30 A at 24 VDC
Contact Termination
PCB
Mounting Style
Panel
Power Consumption
1.7 W
Contact Material
Silver Cadmium Oxide
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
9-1393211-0
PB352

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T92S11D12-24
Manufacturer:
TYCO
Quantity:
10 000
Part Number:
T92S11D12-24-24V
Quantity:
5 400
Part Number:
T92S11D12-24V
Manufacturer:
Potter&Brumfieid
Quantity:
5 400
n
n
n
n
n
n
n
Typical applications
HVAC, residential / commercial appliances, industrial controls
09-2010, Rev. 0910
www.te.com
© 2010 Tyco Electronics Ltd.
Approvals
UL E22575 (Recgonized and Listed); CSA LR15734; VDE REG.Nr. 5386
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
Limiting continuous current
Limiting making current
Limiting breaking current
Contact material
Min. recommended contact load
Frequency of operation, with load
Operate/release time max., including bounce
Contact ratings
Type
UL508
AgCdO
AgSnOInO
VDE
AgCdO, flange mount relays
AgCdO, PC mount relays
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NC
NO
NO
NO
NO
NO
NO
NO
NO
NC
CO
NO
NC
CO
30A, 2 form A (NO) and 2 form C (CO) switching capability
Designed to control compressor loads to 3.5 tons, 110LRA / 25.3FLA
Meets requirements of UL 508 and UL 873 spacings - 8mm through
air, 9.5mm over surface
Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-
contact
Meets requirements of UL Class F construction
UL approved for 600VAC switching (1.5HP)
New screw terminal version (consult factory for availability,
ratings)
Load
40A, 277VAC, resistive (flange mount only)
30A, 120/277VAC, resistive
10A, 600VAC, general purpose
1HP, 120VAC
3HP, 240VAC
1.5HP, 480 or 600VAC
110LRA/25.3FLA, 240VAC (DC coil only)
60LRA/14FLA, 240VAC (AC coil only)
3A, 240VAC, pilot duty
20A, 28VDC, resistive
TV10, 120VAC
3A, 277VAC
2A, 480VAC
1A, 600VAC
30A, 120/277VAC, resistive (DC coil only)
30A, 120/277VAC, resistive (AC coil only)
20A, 480VAC, resistive
1.5HP, 120VAC, 2 pole making/breaking (Fig.1)
3HP, 240VAC, 3 phase (DC coil only)
3HP, 480VAC, 3 phase (DC coil only)
2HP, 600VAC, 3 phase (DC coil only)
20A, 400VAC
3A, 400VAC
20A, 400VAC
30A, 400VAC
3A, 400VAC
30A, 400VAC
1)
500ma (NO)/ 100ma (NC), 12VAC
General Purpose Relays
Power Relays
T92 Series Two-pole 30A PCB or Panel Mount Relay
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
2 form A (NO), 2 form C (CO)
AgSnOInO, AgCdO
30A NO; 3A NC
30A NO; 3A NC
30A NO; 3A NC
30A NO; 3A NC
15/15ms
277VAC
600VAC
360hr
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
200x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
30x10
30x10
30x10
30x10
Cycles
6x10
1x10
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Contact ratings
ARI 780-86 Endurance Test (section 6.6):
Figure 1
Figure 2
1) Contact ratings at 25°C (unless otherwise noted) with relay properly vented.
Mechanical endurance
Coil Data
Coil voltage range
Max. coil power
Max. coil temperature
Coil insulation system according UL
Coil versions, DC coil
Coil versions, AC coil
All figures are given for coil without preenergization, at ambient temperature +23°C.
HVAC Definite Purpose Contactor Standard
Normally Open Contacts
Single Phase Per Pole (Single load per pole)
Coil
code
6
9
12
18
24
48
110
Coil
code voltage
12
24
120
240
277
Single Phase/Two Pole (Both poles together switching a single load)
110 LRA, 18 FLA, 200K operations (DC Coil).
60 LRA, 14 FLA, 200K operations (AC Coil).
110 LRA, 25.3 FLA, 200K operations (DC Coil)
FLA, LRA ratings are compatible with 3.5 ton compressor applications.
110/120
220/240
250/277
Rated
VAC
12
24
voltage
Rated
T1
VDC
110
12
18
24
48
6
9
L1
1)
L1
Frequency
T1
(continued)
50/60
50/60
50/60
Hz
60
60
L2
Operate
voltage
13.5
18
36
82.5
VDC
4.5
6.75
9
L2
T2
Operate
voltage
192
222
T2
VAC
19.2
96
9.6
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
Release
voltage
5 to 110VDC; 12 to 240VAC
11
VDC
Potter & Brumfield
0.6
0.9
1.2
1.8
2.4
4.8
Release
voltage
VAC
12
24
28
1.2
2.4
1.7W; 4.0VA
Class F
155°C
resistance
Ω±10%
resistance
1390
7255
197
350
Coil
Ω±10%
22
48
86
3800
5485
36.6
Coil
950
9.1
10x10
Rated coil
Rated coil
power
power
1.7
1.7
1.7
1.7
1.7
1.7
1.7
VA
6
W
4
4
4
4
4
ops.
1

Related parts for T92S11D12-24

T92S11D12-24 Summary of contents

Page 1

... Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.te.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. Contact ratings ARI 780-86 Endurance Test (section 6.6): HVAC Definite Purpose Contactor Standard Normally Open Contacts ...

Page 2

... Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.te.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Ambient temperature DC coil AC coil Category of environmental protection ...

Page 3

... Coil code: please refer to coil versions table 09-2010, Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.te.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. Terminal assignment Bottom view on pins 2 Form A 1.36 MAX (34 ...

Page 4

... Wash tight  T92S11A12-120  T92S11A12-240  T92S11A22-12 Top sealed  T92S11A22-24  T92S11A22-120  T92S11A22-240  T92S11D12-12 Wash tight  T92S11D12-24  T92S11D12-48  T92S11D12-110  T92S11D22-12 Top sealed  T92S11D22-24 4 09-2010, Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.te.com together with the ‘Definitions’ section. ...

Related keywords