Specifications of MY2K-US-AC120

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
3A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
5.6mA
Coil Voltage
120VAC
Turn On Voltage (max)
96 VAC
Mounting Type
Socket
Termination Style
Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
3A @ 220VAC
Control On Voltage (max)
96 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Other names
MY2K-USAC120
MY2KUSAC120
Q1263486
MY
■ CHARACTERISTICS
Non-latching
Latching
Note: Data shown are of initial value.
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Mechanically
Under rated load
Single contact type
Bifurcated contact type
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Mechanically
Electrically
Mechanically
Under rated load
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Electrically
50 mΩ max.
20 ms max.
20 ms max.
18,000 operations/hour
1,800 operations/hour
100 MΩ min. (at 500 VDC)
Unsealed: 2,000 VAC, 50/60 Hz for 1 minute
Sealed:
Hermetically sealed: 1,000 VAC, 50/60 Hz for 1 minute
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
Unsealed: -55° to 70°C (-67° to 158°F)
Sealed:
Hermetically sealed: 25° to 60°C (77° to 140°F)
35% to 85% RH
Single contact type:
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
Bifurcated contact type:
AC: 50 million operations min.
DC: 20 million operations min. (5 million operations for the sealed/hermetically
sealed types) (at operating frequency of 1,800 operations/hour)
See “Characteristic Data”
Sealed/unsealed: Approx. 35 g (1.23 oz)
Hermetically sealed: Approx. 50 g (1.76 oz)
50 mΩ max.
AC: 30 ms max.; DC: 15 ms max.
AC: 30 ms max.; DC: 15 ms max.
18,000 operations/hour
1,800 operations/hour
100 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity, and between
set and reset coils
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
-55° to 70°C (-67° to 158°F)
45% to 85% RH
100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
Approx. 30 g (1.06 oz)
2
2
(approx. 20 G)
(approx. 20 G)
2
2
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
700 VAC, 50/60 Hz for 1 minute between contacts of same polarity
-55° to 60°C (-67° to 140°F)