HP4-DC24V-F Panasonic Electric Works, HP4-DC24V-F Datasheet
HP4-DC24V-F
Specifications of HP4-DC24V-F
Related parts for HP4-DC24V-F
HP4-DC24V-F Summary of contents
Page 1
... To enable use with DIN rails, DIN terminal sockets are also available. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 10 AMP POWER RELAY TYPICAL APPLICATIONS HP relays enjoy wide use in various applications, particularly in automation controls and remote controls. Applications include: 1. Industrial machinery ...
Page 2
... All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 3 Form C 4 Form C Part No. Part No. HP3-AC6V HP4-AC6V-F HP3-AC12V HP4-AC12V-F HP3-AC24V HP4-AC24V-F HP3-AC48V HP4-AC48V-F HP3-AC100V HP4-AC100V-F HP3-AC115V HP4-AC115V-F HP3-AC200V HP4-AC200V-F HP3-AC220V HP4-AC220V-F HP3-AC240V HP4-AC240V-F HP3-DC6V HP4-DC6V-F HP3-DC12V HP4-DC12V-F HP3-DC24V HP4-DC24V-F HP3-DC48V HP4-DC48V-F HP3-DC100V HP4-DC100V-F HP3-DC110V HP4-DC110V-F ...
Page 3
... HP3-ML-AC100V HP3-ML-AC115V HP3-ML-AC200V HP3-ML-AC220V HP3-ML-AC240V HP3-ML-DC100V HP3-ML-DC110V HP 4 Form C Part No. HP4-L-AC6V-F HP4-L-AC12V-F HP4-L-AC24V-F HP4-L-AC100V-F HP4-L-AC115V-F HP4-L-AC200V-F HP4-L-AC220V-F HP4-L-AC240V-F HP4-L-DC6V-F HP4-L-DC12V-F HP4-L-DC24V-F HP4-L-DC48V-F HP4-L-DC100V-F HP4-L-DC110V-F 3 Form C (direct mount type) Part No. HP3-M-AC6V HP3-M-AC12V HP3-M-AC24V HP3-M-AC48V HP3-M-AC100V HP3-M-AC115V HP3-M-AC200V HP3-M-AC220V HP3-M-AC240V HP3-M-DC6V HP3-M-DC12V HP3-M-DC24V ...
Page 4
HP RATING 1. Coil data 1) AC coils Nominal coil current Contact Nominal coil (mA) arrangement voltage 50Hz 6V AC 349mA 12V AC 181.2mA 24V AC 94mA 48V AC 46.5mA 2 Form C 100V AC 25.3mA 115V AC 23.1mA 200V ...
Page 5
Specifications Characteristics Item Arrangement Initial contact resistance, max Contact 2 Form C, 3 Form C Contact material 4 Form C Nominal switching capacity Rating Min. switching capacity (Reference value)* Insulation resistance (Initial) Between open contacts Breakdown voltage Between contact ...
Page 6
... Coil terminal No. and polarity (DC type) Polarity HP2 (+) 7 Terminal No. (–) 2 Schematic (Bottom view Compatible with tab terminal #205 series receptacle. Tolerance .079 inch: 0.2 .008 .079 to .354 inch: 0.5 .020 .354 to .787 inch: 1 .039 .787 inch: 1.5 .059 HP3 HP4 ...
Page 7
Plug-in type (3 Form C) Plug-in type (4 Form C) 0.8 .031 9 10 5.26 .207 .207 All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. External dimensions 5 8 .197 .315 .197 38 1.496 0.5 .020 44 1.732 5 ...
Page 8
HP TM type (2 Form C) Dimension: Tolerance Max. 2mm .079 inch: 0.2 .008 2 to 9mm .079 to .354 inch: 0.5 .020 9 to 20mm .354 to .787 inch: 1 .039 Min. 20mm .787 inch: 1.5 .059 Direct mounting ...