H5S-WB2 Omron, H5S-WB2 Datasheet - Page 7

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
Connections
H5S-@A@/-@B@ Flush Mounting Models
(2-circuit models)
H5S-@FA@/-@FB@ Surface Mounting Models
(2-circuit models)
Note: 1. The Time Switch output uses a no-voltage contact. An external power supply is required for applications in which a load is driven.
Use a switch or relay as the input contact.
Use a contact that is capable of operating with 5 V, 0.1 A (with a minimum signal input width of 100 ms).
Note: Input must be selected using the “F2: Input selection” step of initial setting mode. For details, refer to Using Advanced Functions on page 23.
Flush mounting models
Surface mounting models
(H5S-@A2@/-@B2@)
(H5S-@FA2@/-@FB2@)
Terminal Arrangement
Input Connection (2-circuit Models Only)
2. The output contact ratings are different for 2-circuit and 4-circuit models.
(Front View)
(Rear View)
source
F G H I
Power
Input
A
Output 2
I
F
Output 1 Power
B
G
B
Output 2
C
H
C
Output 1
J
G
D E
D
source
I
Input
J
(4-circuit models)
(4-circuit models)
(Rear View)
(Front View)
Output 4
Digital Time Switch
Output 2 Output 3
Power
source
F
A
F
A
G
B
Output 3
Output 1 Power
Output 1
G
C
B
H
H
C
I
D
I
source
J
E
D
Output 2
J
E
H5S
Output 4
7

Related parts for H5S-WB2