XH414H-II06E Seiko Instruments, XH414H-II06E Datasheet
XH414H-II06E
Specifications of XH414H-II06E
Related parts for XH414H-II06E
XH414H-II06E Summary of contents
Page 1
... SII Micro Parts Ltd. Arcacentral 13F, 2-1 Kinshi 1-Chome Sumida-ku Tokyo, Japan Address: Postal code: 130-0013 Responsible person: Sales Dep. General Manager Shigeo Niwa Signature: (Not applicable to submit this specification by e-mail) Reflowable XH Capacitor XH414H II06E Approval of Customer version of this spec sheet. P.1/12 STDE-B-XH0414H02RII06E-0010-1 ...
Page 2
Described No. Engineering Initial Release 01 Dept. K. Tomitsuka QA Sec Saito QA Sec. Had added model name in Reflow profile 03 Y. Saito Ver. STDE-B-XH0414H02RII06E-0008-3 QA Sec. Changed seller’s address 04 Y. Saito Ver. STDE-B-XH0414H02RII06E-0010-1 SII Micro ...
Page 3
Cover page for the customer approval History of revision Manufacturer Information Index 1 Application 2 Model 3 Chemical System and Structure 4 Nominal Specifications 5 Characteristics 6 Measuring Methods 7 Test Methods 8 Mounting Methods 9 Indications (Markings) 10 Inspection ...
Page 4
... Recommended Storage conditions 4-9 The voltage at the delivery time STDE-B-XH0414H02RII06E-0010-1 -25°C to +70°C 3.3V or less 0.015 mAh (3.3V to 2.0V) 0.07F (3.3V to 0.0V) Diameter Height Temperature +10°C to +30°C Humidity 60%RH or less (V) P.4/12 Model XH414H 3.3V 70 ohm 4.8mm 1.4mm 0.06g 0.3 Max. ...
Page 5
... Refer to “Leakage Criteria” “Initial” means within one month after deliver. Model XH414H 0.01 mAh or more 50% or more of value measured at 24°C 80% or more of value measured at 24°C 150ohm or less 1000 ohm or less ...
Page 6
Measuring Methods 6-1. Measuring Environment, Meters and Equipment 6-1-1: Environment Testing and Measuring must be conducted under the environment of the normal temperature (24+/-2°C) and the normal humidity (65+/-20%RH), if not specified. 6-1-2: Dimensions For measuring dimension JIS B ...
Page 7
... Measureing Circuit> <Fig. 6-2-2 : Charging and discharging Curve> <Table: 6-2> Model Charging Protective voltage Resistance (E) XH414H 3.30V 100ohm STDE-B-XH0414H02RII06E-0010 ( Test Sample Constant-voltage Power R : Protective Resistance Voltmeter Constant-current Load Device Ammeter T d Charging Discharging Time Current (R) (T) 30 min. 20uA P.7/12 ...
Page 8
Internal Impedance Measure by alternating method with Frequency 1kHz. 6-4. Charging Current (for reference) After test sample is charged in the circuit shown in Fig.6-4 by listed voltage (E) and listed protective resistance (R) for listed time in Table ...
Page 9
... Leakage Resistance Characteristics Test (Thermal Shock Test: Air to Air) Hold capacitor at -10+/-2 ° C for 1 hour then hold it at 60+/-2 ° C for 1 hour. (Camber). Not humidity controlled. Repeat 100 cycles between above conditions. STDE-B-XH0414H02RII06E-0010-1 : -25+/-2 ° C, +24+/-2 ° C, XH414H 3.3V Vc (Rp) 3.3V 100ohm P.9/12 +70+/-2 ° ...
Page 10
... Two characters of the back are used by the manufacturer, and might be omitted. 11 …manufactured in January 200 Example: 2Y ...manufactured in November 200 Abbreviation of month: STDE-B-XH0414H02RII06E-0010-1 Model XH414H 260 ° less Within five seconds Nickel plating or Gold plating 0.5N or more (2) Positive polarity (+) (4) Country of origin Jan ...
Page 11
Inspection (Outgoing and Incoming) 10-1. Lot composition Lot must be composed within the same manufacturing conditions. 10-2. Outgoing Inspection SII Micro Parts Ltd., shall do outgoing inspection before shipping. The inspection items are as below table. The inspection results ...
Page 12
... To draw out the performance of the XH414H to its maximum. When XH414H is discharged by current 10uA or more on the circuit, in some cases, the voltage of XH414H will be going down for around 1 second or less than 1 second. In such cases, Electrolytic condensers/capacitors, which was mounted in parallel, can prevent the voltage drop of XH414H. ...
Page 13
Grade Diagram Bridge Leakage Criteria Criteria The leakage can not be seen by naked eyes, but can be seen by microscope, Leakage which have magnification 15. Leakage The leakage can be seen by ...
Page 14
...
Page 15
...
Page 16
...
Page 17
... Time above 200°C must be max. 80seconds. Total length of profile must be max. 300seconds. Peak Temperature Max.260°C < Underfilling Conditions > Temperature: Max.160°C, Time: Max.10 minutes. Time above 200°C*1 100 150 200 Time(seconds) Model HB414 XH414H Applicable (within 5 seconds) 250 300 TS414H NBS414H ...
Page 18
...
Page 19
...
Page 20
... Capacitor position in emboss tape 1. Model 2. Capacitor position in emboss tape Negative side 3. Quantity / reel MAX. 3600pcs / reel XH414H II06E Positive side SII Micro Parts Ltd. ...
Page 21
...
Page 22
... Doing so may generate gas inside the capacitor, resulting, swelling, catching fire, heat generation or bursting not reverse placement of (+) and (-) SII capacitors have polarity. If the (+) and (-) side of the capacitor is reverse inserted, it may cause a short-circuiting or over discharge of the capacitor on some equipment and it may induce overheating, explosion or fire ...