CST206-2A Triad Magnetics, CST206-2A Datasheet

TRANSF 56MH CRNT SENSE

CST206-2A

Manufacturer Part Number
CST206-2A
Description
TRANSF 56MH CRNT SENSE
Manufacturer
Triad Magnetics
Series
CST206r
Type
Current Senser
Datasheets

Specifications of CST206-2A

Transformer Type
Frequency 20-200kHz
Turns Ratio - Primary:secondary
1 : 200
Inductance
56mH
Current Rating
80A
Dc Resistance (dcr)
3.5 Ohm Max
E.t.
4000V µS
Mounting Type
PCB
Frequency Range
50 Hz to 400 Hz
Primary Impedance
3.5 Ohms
Dimensions
1.075 in L x 0.4 in W x 1.225 in H
Product
Current Sense Transformers
Shielding
Unshielded
Brand/series
CST Series
Configuration
Encapsulated
Current, Primary
80 A
Frequency
20-200 kHz
Number Of Outlets
1
Number Of Turns
200
Phase
1
Resistance, Dc
3.5 Ohms
Resistance, Dc, Primary
250 μOhms (Max.)
Resistance, Dc, Sence
21 Ohms (Max.)
Standards
UL
Temperature Rating
130 °C
Temperature, Operating
+40 °C
Termination
Thru-Hole
Turns Ratio
1:500
Input Current
80A
Dc Resistance Max
3.5ohm
Rohs Compliant
Yes
Transformer Mounting
Through Hole
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
237-1098
: :
Designed for switching power supply applications, Triad current sense
transformers are used to detect the current passing through a conductor.
: :
: :
Designed to monitor current at 250 kHz and
above. These transformers have a primary current
rating of 10 Amps.
: :
C u r r e n t S e n s e Tr a n s f o r m e r s
H i g h F r e q u e n c y
www.TriadMagnetics.com
T e c h n i c a l N o t e s
1. Derate ET product by 32% for 50 kHz, 52% for 100 Hz and 50%
2. Rated primary current renders approximately 40ºC temperature rise.
T e c h n i c a l N o t e s
{mm}
C S T 2 0 6 / 3 0 6 D e s c r i p t i o n
O u t l i n e D i m e n s i o n s
O u t l i n e D i m e n s i o n s
C S E 5 D e s c r i p t i o n
for unidirectional operation.
F i g u r e A
|
22520 B Temescal Canyon Road, Corona, CA 92883
F i g u r e B
Section/
Figure
A
B
A
B
A
B
B
A
B
A
B
A
CSE5-100201
CSE5-100301
CSE5-100401
CSE5-100501
CSE5-100601
CSE5-100701
CSE5-101001
CSE5-101251
3. CST206 models have maximum recommended terminating
4. Primary is inserted through hole in casing.
5. 3 pin or center tapped (CT) models are designed with a T suffix.
CST206-1A
CST206-1T
CST206-2A
CST206-2T
CST206-3A
CST206-3T
CST306-1A
CST306-1T
CST306-2A
CST306-2T
CST306-3A
CST306-3T
Part
No.
resistance of 1 ohm per turn.
Type
No.
These transformers are very reliable and operate effectively over the
frequency range of 20 kHz-200 kHz. They are constructed of UL rated
130ºC materials. Both models are available with a center tap option.
REF 20 kHz
ET VμSEC
2000
2000
4000
4000
6000
6000
1000
1000
2000
2000
500
500
@ 10kHz
N1:N2
Turns
1:20
1:30
1:40
1:50
1:60
1:70
1:100
1:125
Tuurns
100 CT
200 CT
300 CT
100 CT
200 CT
Count
50 CT
100
200
300
100
200
50
|
Phone 951-277-0757
Ind. mH
130.0
130.0
Min.
14.0
14.0
56.0
56.0
14.0
14.0
55.0
55.0
3.5
3.5
Inductance
Secondary
μH Min.
2000
3000
180
320
500
720
980
80
DCR Max. Ohms
12.400
12.400
3.500
3.500
1.550
1.550
3.750
3.750
.580
.580
.340
.580
|
FAX 951-277-2757
Secondary
m Max
1140
1500
1750
4750
5500
8500
Pri. Amps
DCR
110.0 RMS
110.0 RMS
550
870
80.0 RMS
80.0 RMS
70.0 RMS
70.0 RMS
35.0 RMS
35.0 RMS
25.0 RMS
25.0 RMS
25.0 RMS
25.0 RMS

Related parts for CST206-2A

CST206-2A Summary of contents

Page 1

... Both models are available with a center tap option. Section/ Type ET VμSEC Tuurns Figure No. REF 20 kHz Count A CST206-1A 2000 100 B CST206-1T 2000 100 CT A CST206-2A 4000 200 B CST206-2T 4000 200 CT A CST206-3A 6000 300 B CST206-3T 6000 300 CT B CST306-1A 500 ...

Page 2

... Turns ratio: Primary to sense 1:500 2. Suggested burden resistor: 60 ohms. 3. Typical ouput: 110 mV /Amp Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate effectively between 50-60 Hz. They are constructed of UL rated 130ºC materials ...

Related keywords