Page 1
... SOT-23 package or 8-lead MSOP package. It contains a band gap temperature sensor and 10-bit ADC to monitor and digitize the temperature reading to a resolution of 0.25°C. The AD7814 has a flexible serial interface that allows easy inter- facing to most microcontrollers. The interface is compatible ® with SPI , QSPI™ ...
Page 2
... AD7814–SPECIFICATIONS Parameter TEMPERATURE SENSOR AND ADC Accuracy Resolution Update Rate Temperature Conversion Time SUPPLIES Supply Voltage Supply Current Normal Mode Shutdown Mode ( Shutdown Mode ( Power Dissipation Power Dissipation 1 sps 10 sps 100 sps 3 DIGITAL INPUT Input High Voltage, V ...
Page 3
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the AD7814 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality ...
Page 4
... Positive Supply Voltage, 2 5.5 V Serial Clock Input. This is the clock input for the serial port. The serial clock is used to clock data out of the temperature value register of the AD7814 and to clock data into the control register on the part. Chip Select Input. Logic input. The device is selected when this input is low. ...
Page 5
... To ensure that no lock- out signal is set, bring the CS low at a greater or less time than 350 µs (± 30%). This will mean that the AD7814 is not inter- rupted during a conversion process. The AD7814 can be placed in a shutdown mode, via the control register, in which case the on-chip oscillator is shut down and no further conversions are initiated until the AD7814 is taken out of shutdown mode ...
Page 6
... At the end of the read operation, the DOUT line remains in the state of the last bit of data clocked out of the AD7814 until CS returns high, at which time the DOUT line goes into three-state. ...
Page 7
... Care should be taken to ensure that this is in good thermal contact with the surface being measured. SDI As with any IC, the AD7814 and its associated wiring and cir- RA1 cuits must be kept free from moisture to prevent leakage and corrosion, particularly in cold conditions where condensation is more likely to occur ...
Page 8
... AD7814 INDICATOR 0.15 MAX Revision History Location 8/04—Data Sheet Changed from REV REV. E. Changes to ORDERING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Changes to CONVERTER DETAILS section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Changes to Read Operation section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Updated OUTLINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5/02—Data Sheet Changed from REV REV. D. Updates to SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 OUTLINE DIMENSIONS 6-Lead Small Outline Transistor Package [SOT-23] ...