CM400DY-24NF Powerex Inc, CM400DY-24NF Datasheet
CM400DY-24NF
Specifications of CM400DY-24NF
Available stocks
Related parts for CM400DY-24NF
CM400DY-24NF Summary of contents
Page 1
... Applications: £ AC Motor Control £ UPS £ Battery Powered Supplies Ordering Information: Example: Select the complete part module number you de- sire from the table below -i.e. CM400DY-24NF is a 1200V (V ), 400 Ampere Dual IGBT- CES MOD™ Power Module. Type Current Rating V ...
Page 2
... 15V, R d(off) GE1 GE2 t Inductive Load f t Switching Operation 400A does not exceed T j should be measured just under the chips. th(f-a) Symbol CM400DY-24NF T –40 to 150 j T –40 to 125 stg V 1200 CES V ±20 GES I 400 C I 800 400 E I 800 1470 C — ...
Page 3
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM400DY-24NF Dual IGBTMOD™ NF-Series Module 400 Amperes/1200 Volts Thermal and Mechanical Characteristics, T Characteristics Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Contact Thermal Resistance External Gate Resistance ...
Page 4
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM400DY-24NF Dual IGBTMOD™ NF-Series Module 400 Amperes/1200 Volts REVERSE RECOVERY CHARACTERISTICS (TYPICAL 600V ±15V 0.73Ω 25°C j Inductive Load EMITTER CURRENT (AMPERES) E SWITCHING LOSS VS. GATE RESISTANCE (TYPICAL 600V ±15V 400A ...