ATS48D47Y SQUARE D, ATS48D47Y Datasheet

no-image

ATS48D47Y

Manufacturer Part Number
ATS48D47Y
Description
SOFT START 208-690VAC 47A ATS48
Manufacturer
SQUARE D
Datasheet
Product data sheet
Characteristics
Complementary
Mar 30, 2012
Assembly style
Function available
Power supply voltage limits
Power supply frequency
Power supply frequency limits
Factory setting current
Control circuit voltage
Control circuit consumption
Discrete output number
Discrete output type
Output absolute accuracy precision
Minimum switching current
Maximum switching current
ATS48D47Y
soft starter for asynchronous motor - ATS48 -
40 A - 208..690 V - 11..37 KW
Main
Range of product
Product or component
type
Product destination
Product specific appli-
cation
Component name
Power supply voltage
Motor power kW
Motor power hp
Power dissipation in W
Utilisation category
Type of start
Icl nominal current
IP degree of protection
With heat sink
External bypass (optional)
177...759 V
50...60 Hz (- 5...5 %)
47.5...63 Hz
40 A
110 - 15 % to 230 + 10 %, 50/60 Hz
30 W
2
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
+/- 5 %
Relay outputs 10 mA at 6 V DC
Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5, L/R = 20 ms
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5, L/R = 20 ms
Altistart 48
Soft starter
Asynchronous motors
Pumping and ventilation machine
Severe and standard applications
ATS48
208...690 V (- 15...10 %)
11 kW at 230 V for standard applications
22 kW at 400 V for standard applications
22 kW at 440 V for standard applications
22 kW at 500 V for severe applications
22 kW at 525 V for severe applications
30 kW at 500 V for standard applications
30 kW at 525 V for standard applications
30 kW at 660 V for severe applications
30 kW at 690 V for severe applications
37 kW at 660 V for standard applications
37 kW at 690 V for standard applications
9 kW at 230 V for severe applications
18.5 kW at 400 V for severe applications
18.5 kW at 440 V for severe applications
10 hp at 208 V for severe applications
15 hp at 230 V for standard applications
25 hp at 460 V for severe applications
30 hp at 460 V for standard applications
30 hp at 575 V for severe applications
40 hp at 575 V for standard applications
116 W for standard applications
142 W for standard applications
AC-53A
Start with torque control (current limited to 5 In)
38 A for standard applications
47 A for standard applications
IP20
1

Related parts for ATS48D47Y

ATS48D47Y Summary of contents

Page 1

... Control circuit voltage Control circuit consumption Discrete output number Discrete output type Output absolute accuracy precision Minimum switching current Maximum switching current Mar 30, 2012 ATS48D47Y soft starter for asynchronous motor - ATS48 - 208..690 V - 11..37 KW Main Range of product Altistart 48 Product or component Soft starter ...

Page 2

Discrete input number Discrete input type Discrete input voltage Discrete input logic Starting current Analogue output type Communication port protocol Connector type Communication data link Physical interface Transmission rate Max nodes number Protection type Marking Type of cooling Operating position ...

Related keywords