K8AC-CT200L

Manufacturer Part Number
K8AC-CT200L
Description
20-200A Current Transformer
Manufacturer
Omron
Datasheet

Specifications of K8AC-CT200L

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Ideal for current monitoring for industrial
facilities and equipment.
• Monitor for overcurrents or undercurrents.
• Manual resetting and automatically resetting supported by one
• Startup lock and operating time can be set separately.
• One SPDT output relay, 6 A at 250 VAC (resistive load).
• Output relay can be switched between normally open and
• Process control signal (4 to 20 mA) supported.
• Commercial CT input signal (0 to 1 A, 0 to 5 A) supported.
• Output status can be monitored using LED indicator.
Model Number Structure
■ Model Number Legend
1. Basic Model
2. Functions
3. Measuring Current
Note: The K8AB-AS3 is specially designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT). (Direct input is
4. Supply Voltage
Cat. No. N142-E1-02
K8AB-@@
Relay.
normally closed.
Single-phase Current Relay
K8AB-AS
K8AB: Measuring and Monitoring Relays
AS:
1:
2:
3:
24 VDC:
24 VAC:
100-115 VAC: 100 to 115 VAC
200-230 VAC: 200 to 230 VAC
1
not possible.)
Single-phase Current Relay (One-sided operation)
2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC
0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC
10 to 100 A AC, 20 to 200 A AC (See note.)
2 3
24 VDC
24 VAC
4
Single-phase Current Relay
K8AB-AS
1

Related parts for K8AC-CT200L

K8AC-CT200L Summary of contents

Page 1

... Measuring Current AC/DC 100 mA AC/DC 500 mA AC/ AC/DC, 0 AC/DC, 0 AC/ 100 A AC 200 A AC (See note.) Note: The K8AB-AS3 is specially designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.) 4. Supply Voltage 24 VDC: 24 VDC 24 VAC: 24 VAC ...

Page 2

... The inputs and power supply are connected internally malfunction may occur due to an unwanted current path if the inputs and power supply are connected to the same line unwanted current path exists, use a K8AB AC Power Supply or isolate with an external power supply. 2. The K8AB-AS3 is designed to be used in combination with an OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.) ■ Accessory (Order Separately) ...

Page 3

... K8AB-AS1 AC/ 100 mA AC/ 500 mA AC/DC K8AB-AS2: 0 AC/DC 0 AC/DC 0 AC/DC K8AB-AS3: When used together with a K8AC-CT200L Current Transformer 10 to 100 200 A AC 100% operation at set value 5% to 50% of operating value Manual reset/automatic reset (switchable) Note: Manual reset: Turn OFF power supply for longer. ...

Page 4

Specifications Allowable power supply voltage range Allowable power supply frequency range Input frequency range Overload capacity Setting error Operating value Reset value Operating time Startup lock time Repeat error Operating value Reset value Operating time Startup lock time Temperature ...

Page 5

... Load Load Note: The K8AB-AS3 is designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT). The 24-VDC power supply type is a non-insulated power supply. The inputs and power supply are connected internally malfunction may occur due to an unwanted current path if the inputs and power supply are connected to the same line ...

Page 6

Nomenclature ■ Front Terminal block (See notes 1 and 2.) Power indicator Relay status indicator Alarm indicator Terminal block (See notes 1 and 2.) 6 Single-phase Current Relay Indicators Power indicator (PWR: Green) Relay status indicator (RY: Yellow) Alarm indicator ...

Page 7

... Malfunctions may occur if the input is connected to unused terminals and the Unit will not operate correctly. Terminal I1 is not used by the K8AB-AS3. If using the OMRON K8AC-CT200L CT, connect to terminals k and l on the K8AC-CT200L. (Terminals kt and lt are not used.) 2. Power Supply Connect the power supply to terminals A1 and A2. ...

Page 8

... The startup lock time will start when the input current reaches 30% or more of the current setting. Use startup lock time to prevent unwanted operation, e.g result of inrush current. Dimensions Single-phase Current Relays K8AB-AS1 K8AB-AS2 K8AB-AS3 OMRON CT K8AC-CT200L 8 Single-phase Current Relay 22.5 9.3 9.3 1.7 1.7 4.7 ...

Page 9

... DC input, use a SELV power-supply capable of overcurrent protection. Specifically, a SELV power-supply has a double or reinforced insulation for input and output, and output voltage of 30 Vr.m.s with 42 peak or DC60V maximum. Recommended power-supply: Model S8VS-06024@. (Omron product) Cat. No. N142-E1-02 ■ Precautions for Correct Use For Proper Use 1 ...

Page 10

... K8AB-AS2-J. When monitoring a device that has a large starting current such as a motor, use the K8AB-AS3-J. Adjust the number of conductor windings so that a minimum flows to the primary side of the K8AC-CT200L CT. Increasing the number of windings will simulate an increase in current. Minimize the operating time (0.1 s) for this application ...

Page 11

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 12

Cat. No. N142-E1-02 12/06 Specifications subject to change without notice Printed in USA ...