ADG732 Analog Devices, ADG732 Datasheet
ADG732
Available stocks
Related parts for ADG732
ADG732 Summary of contents
Page 1
... Automatic Test Equipment GENERAL DESCRIPTION The ADG726/ADG732 are monolithic CMOS 32 channel/dual 16 channel analog multiplexers. The ADG732 switches one of thirty-two inputs (S1-S32 common output determined by the 5-bit binary address lines A0, A1, A2, A3 and A4. The ADG726 switches one of sixteen inputs as determined by the four bit binary address lines, A0, A1, A2 and A3 ...
Page 2
... Bandwidth C (OFF (OFF) D ADG726 ADG732 (ON ADG726 ADG732 POWER REQUIREMENTS I DD NOTES 1 Temperature range is as follows: B Version: –40°C to +85°C. 2 Guaranteed by design, not subject to production test. Specifications subject to change without notice ± 10 Version –40°C ...
Page 3
... MHz typ 13 pF typ 180 pF typ 360 pF typ 200 pF typ 400 pF typ 10 µA typ 20 µA max –3– ADG726/ADG732 Test Conditions/Comments mA Test Circuit ...
Page 4
... Bandwidth C (OFF (OFF) D ADG726 ADG732 (ON ADG726 ADG732 POWER REQUIREMENTS NOTES 1 Temperature range is as follows: B Version: –40°C to +85°C. 2 Guaranteed by design, not subject to production test. Specifications subject to change without notice. 1 Dual Supply B Version –40°C ...
Page 5
... Address, Enable Hold Time ) and timed from a voltage level Figure 1. Timing Diagram . The ADG726 has two –5– ADG726/ADG732 Setup Time Hold Time cycles + V )/ inputs. This enables the part to be used ...
Page 6
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADG726/ADG732 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality ...
Page 7
... Table 2. ADG732 Truth Table ...
Page 8
... PRELIMINARY TECHNICAL DATA ADG726/ADG732 V Most positive power supply potential Most Negative power supply in a dual supply application. In single supply applications, connect to GND Positive supply current Negative supply current Ground (0 V) reference. S Source terminal. May be an input or output. ...
Page 9
... TPC 5. On Resistance as a Function for Different Temperatures Dual Supply TPC 6. Leakage Currents as a function –9– ADG726/ADG732 TPC 7. Leakage Currents as a function TPC 8. Leakage Currents as a function TPC 9 ...
Page 10
... PRELIMINARY TECHNICAL DATA ADG726/ADG732 TPC 10. Leakage Currents as a Function of Temperature TPC 11. Supply Currents vs. Input Switching Frequency TPC 12. Charge Injection vs. Source Voltage TPC 13 Times vs. ON OFF Temperature TPC 14. Off Isolation vs. Frequency TPC 15. Crosstalk vs. Frequency –10– ...
Page 11
... OUT R L 35pF 300 V S32 3V ADDRESS DRIVE ( OUT V OUT 35pF 300 Test Circuit 6. Break Before Make Delay, t –11– ADG726/ADG732 (OFF S32 V D +0.8V EN GND Test Circuit 3. I (OFF) D ...
Page 12
... D V OUT SWITCH 35pF 300 OUTPUT 0V Test Circuit 8. Enable Delay +2.4V LOGIC RS INPUT ( ADG732 OUT C L 1nF V OUT Test Circuit 9. Charge Injection. A4 NETWORK ANALYZER OUT Test Circuit 11. Channel-to-Channel Crosstalk. ...
Page 13
... BSC 0.037 (0.95 SEATING PLANE TOP VIEW (PINS DOWN) 0.006 (0.15 0.002 (0.05) 0° MIN 0° – 7° 0.008 (0.20) 0.011 (0.27) 0.019 (0.5) 0.004 (0.09) BSC 0.006 (0.17) –13– ADG726/ADG732 0.010 (0.25) MIN 48 1 0.207 (5.25) BOTTOM 0.201 (5.10) SQ VIEW 0.195 (4.95 0.217 (5.5) REF ...