Disc Ceramic Capacitors
Safety Ceramic Capacitors
DEFINITIONS (IEC 384-14 1993)
X FUNCTION: applications where the capacitor failure
does not lead to danger of electrical shock. There are
three subclasses related to the peak voltage of the
impulses superimposed to the mains voltage:
Subclass X1: impulses up to 4000V
Subclass X2: impulses up to 2500V
Subclass X3: impulses up to 1200V
Y FUNCTION: applications where the capacitor failure
may lead to danger of electrical shock. There are four
subclasses related to the peak voltage of the impulses
applied before the life test:
Subclass Y1: impulses up to 8000V
Subclass Y2: impulses up to 5000V
Subclass Y3: rated 250Vac without impulses
Subclass Y4: impulses up to 2500V
HOW TO ORDER
PERFORMANCE CHARACTERISTICS
CERTIFICATION BODY APPROVALS
Product Code
* Main reference voltage
CAS CAN/CSA - C22.2 No. 1-94
VDE
IMQ
UL
Measured at
Capacitance Tolerance
D.F max. @ 25ºC
Insulation Resistance (IR)
Test Voltage Between Leads*
Test Voltage Leads to Body
Operating Temperature Range (ºC)
61
DIN EN 132400: 1995
IEC 384-14: 1993
IEC 384-14: 1993
EN 132400: 1994
DIN BDE 0560
Standard
UL 1414
Part 2
Voltage
V
Certificate
E 147842 (N)
LR 100430-2
Number
94612
94610
94634
V4551
–
Capacitance
101
X1: 400 VAC
Y1: 250 VAC
X1: 400 VAC
Y1: 250 VAC
Voltage
250 VAC
250 VAC
Rated
61V
–
1.0 kHz / 0.3 Vrms / 25ºC
±20% / -20 +50%
Tolerance
4.000 VAC
4.000 VAC
-40 +125
40/125/21/C
≥ 10 GΩ
Category
40/85/21/C
Climatic
1.5%
61V
K
Certificate
E 147842 (N)
LR 100430-1
Number
Forming
101384
76830
76804
V4635
Lead
B
ANTENNA: the capacitors are used to decouple the
antenna leads of video and audio equipment, whose
failure may lead to danger of electrical shock.
TPC Safety Capacitors:
61V (GZO): meets subclasses X1, Y1 Test voltage 4000 VAC
62O (GKO): meets subclasses X1, Y2 Test voltage 2500 VAC
65N (GAY): meets subclasses X2, Y3 Test voltage 1800 VAC
1.0 kHz / 0.3 Vrms / 25ºC
X1: 400 VAC
Y1: 250 VAC
X1: 400 VAC
Y2: 250 VAC
Voltage
250 VAC
250 VAC
400 VAC
Capacitor
Rated
Diameter
62O
±20% / -20 +50%
D
2.500 VAC
2.500 VAC
-40 +125
≥ 10 GΩ
62O
1.5%
40/125/21C
Category
40/85/21/C
Climatic
25/85/21
Finishing
C
Certificate
E 147842 (N)
Number
–
–
–
–
Packaging
1.0 kHz / 0.3 Vrms / 25ºC
A
±20% / -20 +50%
Voltage
250 VAC
Rated
1.800 VAC
1.800 VAC
65N
-40 +125
≥ 10 GΩ
–
–
–
–
65N
1.5%
Category
Climatic
–
–
–
–
–
17