67101971 Weidmuller, 67101971 Datasheet

CIRCUIT BRKR BUS BAR 3POLE 1M

67101971

Manufacturer Part Number
67101971
Description
CIRCUIT BRKR BUS BAR 3POLE 1M
Manufacturer
Weidmuller
Datasheet

Specifications of 67101971

Accessory Type
Bus Bar
For Use With/related Products
Circuit Breaker; 9926
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
281-2563
Circuit Breakers
Hydraulic Magnetic Type
• Single pole and double pole versions
• 120/240 VAC, 50/60 Hz
• Up to 25A
• Just 13 mm wide
• Mounts on 35mm DIN-rail
• cULus listed according to UL489 CSA C22.2
Voltage
Current
Interrupting capacity
Dielectric strength
Insulation resistance
Operating life
Operating temperature
Wire size*
Torque
cULus listed according to UL489 CSA C22.2 No. 5.02, CE, VDE
Bus-bar (1 pole, insulated, 1 m)
Bus-bar (2 pole, insulated, 1 m)
Bus-bar end cap, 1 pole
Bus-bar end cap, 2 pole
Power lug, straight
Power lug, 90°
Lock-out handle
*Wire sizes: gauges specified are the minimum allowable as per CSA
and UL standards.
The 9926 circuit breakers do not have provisions for marking tags.
A possible solution is to cut the adhesive SchS2 tag rail to length
(approximately 20 mm on a single pole unit so the current rating
remains visible or approximately 30 mm on a two pole unit).
The SchS2 accepts DEK, WS and ESG 8/17 marking tags.
The part number for adhesive SchS2 is 1720600000.
Trip Curves—Hydraulic Magnetic Type
Typical time/current characteristics at 30ºC
minimum
(sec)
maximum 300
(sec)
Although the 9926 series uses a magnetic only trip mechanism, CSA
testing indicates a trip characteristic similar to thermal magnetic trip
mechanisms. No de-rating is required at elevated temperatures.
Additional trip curves and amp ratings are available
upon request.
Technical Data
Approval
Accessories
Sample trip characteristics - KM
No. 5.02, CE, VDE
minimum
maximum
0.5-15A:
20-25A:
125% 150% 200% 400% 600% 800% 1000%
15
90
8
Ordering Data
28
4
10000 mechanical operations
0.7
14AWG min., 10AWG max.
4
120/240 VAC, 50/60Hz
0.09 0.007 0.005
1.5
9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – A C Ve r s i o n
1500V, 50/60Hz
0.6
10AWG min.
-40…+65°C
67101904
67101972
67101973
67101974
67101960
67101961
67101913
Part No.
10,000A
20 in.-lb
100MM
0.4
0.5A
25A
9926 Series
Single Pole
Current Ratings
9926 Series AC Version - dimensions in mm (in.)
9926 Series–AC version Trip Curve
(amps)
0.5
10
13
15
16
20
25
1
2
3
4
5
6
7
8
Trip Curve 1 applies to the following part numbers where
"XX" is the current rating:
Single Pole— 99262512XX
0.001
1000
0.01
100
0.1
Type: Single Pole (up to 120 VAC)
10
10
1
1
(0.2)
5
9926251000
9926251001
9926251002
9926251003
9926251004
9926251005
9926251006
9926251007
9926251008
9926251010
9926251013
9926251015
9926251016
9926251020
9926251025
Part No.
TS 35
(0.75)
19
(1.26)
(%) Rated Current
32
(1.77)
45
(2.55)
(2.6)
64.8
(2.91)
66
74
Ambient Temperature 30°C
Operating Characteristics
QL-1-13-DM-KM-0.5
QL-1-13-DM-KM-01
QL-1-13-DM-KM-02
QL-1-13-DM-KM-03
QL-1-13-DM-KM-04
QL-1-13-DM-KM-05
QL-1-13-DM-KM-06
QL-1-13-DM-KM-07
QL-1-13-DM-KM-08
QL-1-13-DM-KM-10
QL-1-13-DM-KM-13
QL-1-13-DM-KM-15
QL-1-13-DM-KM-16
QL-1-13-DM-KM-20
QL-1-13-DM-KM-25
Description
Curve 1
Double Pole— 99262522XX
(0.51)
13
9926 Series
Double Pole
Current Ratings
9926 Series–AC version Trip Curve
(amps)
0.5
10
13
15
16
20
25
(1.02)
(0.51)
1
2
3
4
5
6
7
8
26
13
Type: Double Pole (up to 240 VAC)
0.001
1000
0.01
100
0.1
10
10
1
1
9926252000
9926252001
9926252002
9926252003
9926252004
9926252005
9926252006
9926252007
9926252008
9926252010
9926252013
9926252015
9926252016
9926252020
9926252025
Part No.
TS 35
(%) Rated Current
Ambient Temperature 30°C
Operating Characteristics
QL-2-13-DM-KM-0.5
QL-2-13-DM-KM-01
QL-2-13-DM-KM-02
QL-2-13-DM-KM-03
QL-2-13-DM-KM-04
QL-2-13-DM-KM-05
QL-2-13-DM-KM-06
QL-2-13-DM-KM-07
QL-2-13-DM-KM-08
QL-2-13-DM-KM-10
QL-2-13-DM-KM-13
QL-2-13-DM-KM-15
QL-2-13-DM-KM-16
QL-2-13-DM-KM-20
QL-2-13-DM-KM-25
Curve KM
Description
49

Related parts for 67101971

Related keywords