BDTA4 Cooper/Bussmann, BDTA4 Datasheet

no-image

BDTA4

Manufacturer Part Number
BDTA4
Description
FUSE ADAPTOR KIT 400A TYPE T
Manufacturer
Cooper/Bussmann
Type
Fuse Adapter Kitr
Datasheet

Specifications of BDTA4

Switch Type
Disconnect Switch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage
-
Lead Free Status / Rohs Status
Compliant
Catalog Symbols*: FD200J3, FD400J3, FD600J3,
Ampere Rating: 200, 400, 600, 800 Amperes
Voltage Rating: 600 Volts
Agency Approvals:
UL Listed, Guide WPZX, File E155130
CSA Certified, File 58077M9
IEC 947-1
General Information:
Bussmann fused disconnect switches are UL 98/CSA 22.2 No. 4
devices. This makes them suitable for use on service equipment,
panel boards, switchboards, industrial control equipment, motor
control centers, etc.
*Catalog symbol is for switch only. Handles and shafts are ordered separately.
The only controlled copy of this BIF document is the electronic read-only version located on
the Bussmann Network Drive. All other copies of this document are by definition uncon-
trolled. This bulletin is intended to clearly present comprehensive product data and provide
technical information that will help the end user with design applications. Bussmann reserves
the right, without notice, to change design or construction of any products and to discontinue
or limit distribution of any products. Bussmann also reserves the right to change or update,
without notice, any technical information contained in this bulletin. Once a product has been
selected, it should be tested by the user in all possible applications.
Disconnect Switch
Fusible, 200-800A, 600V
FD200J3
FD400J3
FD600J3
FD800L3
†Class J fuses are standard. For 600V, Class T fuses, see table below.
Class T Adapters
200A
400A
600A
12-17-98
SB98107
FD800L3
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
Rev. A
BDTA2
BDTA4
BDTA6
Fuse
Type
J†
J†
J†
L
FD200J3
200V
100
150
200
50
Maximum Horsepower Rating
208V
125
150
200
50
240V
125
200
250
60
480V
125
250
400
500
600V
150
350
500
600
FD400J3
Components:
Handles
Style
Pistol
Pistol
Pistol 1, 3R, 4, 4X, 12 Blk
Terminal Lug Kits - Kit Includes 6 Lugs
Shafts
**Mounting depth is the distance from the outside of door to the disconnect switch mounting
Accessories:
Fuse Covers and Terminal Shrouds (line-side)
600, 800
‡Fuse covers come standard on 200-800 amp switches.
Auxiliary Contacts - F200 through F800
Amp Rating Amp Rating
10.22 - 14.54
14.78 - 19.10
17.53 - 21.85
20.28 - 24.62
10.04 - 12.83
11.20 - 14.00
12.98 - 15.77
15.76 - 18.55
18.51 - 21.30
21.06 - 24.08
Amp Rating
Rating
7.87 - 12.20
9.05 - 13.38
12.0 - 16.32
plate. Shaft can be cut to desired length.
Mounting Depth**
200-800
600 & 800
Amp
Switch
200
400
200
400
1, 3R, 12
1, 3R, 12
NEMA
Type
Switch Type
Aux. Contact
J or T
Fuse
Type
J or L
J
(2) #2 - 600 kcmil
10
Color (Inches) Marking
#6 - 300 kcmil
#2 - 600 kcmil
Wire Size
200 - 400 Amps (
600 - 800 Amps (
Blk
Blk
200-800A (
200A (
Voltage
Length
Grip
4.72
5.71
5.71
Voltage
Shaft Length
600V
600V
600V
600
11.00
12.78
15.56
18.31
21.06
11.00
12.78
15.56
18.31
21.06
8.66
9.84
9.84
FD200 through
0.47˝ x 0.47˝)
Wire Type
Off/On
Off/On
Off/On
Catalog Number Catalog Number
1 N.O. & 1 N.C.
FD600J3, FD800L3
0.47˝ x 0.47˝)
Fuse Covers
Cu/Al
Cu/Al
Cu/Al
0.47˝ x 0.47˝)
0.47˝ x 0.47˝)
BFDC200‡
BFDC400‡
BFDC600‡
BDAUX1
Catalog
Number
Padlock- Defeat-
able
Yes
Yes
Yes
Kit Catalog Number
Bussmann
Terminal Shrouds
Catalog Number
2 N.O. & 2 N.C.
FD800
BDTL25
BDTL26
BDTL27
able
Yes
Yes
No
BDAUX2
BDS220
BDS250
BDS280
BDS325
BDS395
BDS465
BDS535
BDS250
BDS280
BDS325
BDS395
BDS465
BDS535
Number
Catalog
BDTSF2
BDTSF4
BDTSF6
BIF Doc #1122
Form No. FD
Page 1 of 2
Catalog
Number
BDH53
BDH16
BDH35
®

Related parts for BDTA4

BDTA4 Summary of contents

Page 1

... J fuses are standard. For 600V, Class T fuses, see table below. Class T Adapters 200A BDTA2 400A BDTA4 600A BDTA6 CE logo denotes compliance with European Union Low Voltage Directive (50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. ...

Page 2

Disconnect Switch Fusible, 200-800A, 600V Dimensional Data 200 Amps 0.27 Dia. 6.8 1.84 8.88 46.7 225.5 9.87 250.7 2.25 1.51 57.1 0.28 38.3 1.90 7.1 7.84 48.2 199.1 7.80 (2 Pole) 10.25 (3 Pole) 12.68 (4 Pole) 260.3 198.1 400 ...

Related keywords