0224008.HXUP Littelfuse Inc, 0224008.HXUP Datasheet - Page 3

FUSE 125V FAST 2AG 8A AXIAL

0224008.HXUP

Manufacturer Part Number
0224008.HXUP
Description
FUSE 125V FAST 2AG 8A AXIAL
Manufacturer
Littelfuse Inc
Series
224Pr
Type
Axial Lead Fusesr
Datasheets

Specifications of 0224008.HXUP

Fuse Type
Fast Acting
Voltage - Rated
125VAC
Current
8A
Package / Case
Axial, 2AG, 5x15mm
Size / Dimension
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
Mounting Type
Through Hole
Dc Cold Resistance
0.01 Ohm
Melting I²t
56
Current Rating
8 Amps
Voltage Rating
125 Volts
Fuse Size / Group
2AG
Termination Style
Axial
Body Material
Glass
Dimensions
14.48 mm L x 4.7 mm W
Product
Axial Lead and Cartridge Fuses
Interrupt Rating
500 Amps at 125 VoltsAC
Mounting Style
Through Hole
Operating Temperature Range
- 55 C to + 125 C
Resistance
0.01 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
0224008.HXP
224008.P
224008P
F2442
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
(.177")
Please refer to www.littelfuse.com/series/224.html
or /225.html for current information.
Product Characteristics
Materials
Terminal Strength
Solderability
Product Marking
Dimensions
4.5
225 000P Series
14.48
(.57")
Body : Glass
Cap : Nickel–plated brass
Leads: Tin–plated Copper
Test Condition A
2003-01 Annex A
Cap1 : Brand logo, current and Voltage
Ratings
Cap2 : Series and Agency approval Mark
4.7 (.184")
224 000P Series
14.48
(.57")
Axial Lead & Cartridge Fuses
2AG > Fast Acting > 224/225 Series
(1.50") TYP.
38.1
(.025")
.635
257
Note: The ratings from 4A to 10A with MXUP in
the suffix
Operating
Temperature:
Thermal
Shock:
Vibration
Humidity
Salt Spray
Part Numbering System
Packaging Code
Lead-free
Series
Amp Code
Quantity Code
X = Filler
Refer to Amp Code column of
Electrical Characteristics Table
M = 1000
240 hours
0224
xxxx
M X P
224/225 Series

Related parts for 0224008.HXUP