Z8F022ASJ020SC Zilog, Z8F022ASJ020SC Datasheet - Page 37

IC ENCORE XP MCU FLASH 2K 28SOIC

Z8F022ASJ020SC

Manufacturer Part Number
Z8F022ASJ020SC
Description
IC ENCORE XP MCU FLASH 2K 28SOIC
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheets

Specifications of Z8F022ASJ020SC

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, LVD, POR, PWM, Temp Sensor, WDT
Number Of I /o
23
Program Memory Size
2KB (2K x 8)
Program Memory Type
FLASH
Eeprom Size
64 x 8
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
28-SOIC (7.5mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3355

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F022ASJ020SC
Manufacturer:
Zilog
Quantity:
372
PS022825-0908
Note: Not to Scale
Internal Precision
Internal RESET
V
Oscillator
Oscillator
CC
Crystal
signal
Voltage Brownout Reset
= 0.0 V
V
V
POR
VBO
The devices in the Z8 Encore! XP F082A Series provide low Voltage Brownout (VBO)
protection. The VBO circuit senses when the supply voltage drops to an unsafe level
(below the VBO threshold voltage) and forces the device into the Reset state. While the
supply voltage remains below the Power-On Reset voltage threshold (V
block holds the device in the Reset.
After the supply voltage again exceeds the Power-On Reset voltage threshold, the device
progresses through a full System Reset sequence, as described in the Power-On Reset
section. Following Power-On Reset, the POR status bit in the Reset Status (RSTSTAT)
register is set to 1.
teristics
The Voltage Brownout circuit can be either enabled or disabled during STOP mode.
Operation during STOP mode is set by the VBO_AO Flash Option Bit. See
Bits
for information about configuring VBO_AO.
on page 221 for the VBO and POR threshold voltages (V
Figure 5. Power-On Reset Operation
Figure 6
counter delay
displays Voltage Brownout operation. See
POR
Reset, Stop Mode Recovery, and Low Voltage Detection
Oscillator
optional XTAL
Start-up
counter delay
Z8 Encore! XP
Product Specification
VBO
Execution
Electrical Charac-
and V
Program
POR
®
F082A Series
), the VBO
Flash Option
V
POR
CC
).
= 3.3 V
26

Related parts for Z8F022ASJ020SC