AT89C51AC3-S3SUM Atmel, AT89C51AC3-S3SUM Datasheet - Page 124

IC 8051 MCU 64K FLASH 52-PLCC

AT89C51AC3-S3SUM

Manufacturer Part Number
AT89C51AC3-S3SUM
Description
IC 8051 MCU 64K FLASH 52-PLCC
Manufacturer
Atmel
Series
89Cr
Datasheet

Specifications of AT89C51AC3-S3SUM

Core Processor
8051
Core Size
8-Bit
Speed
60MHz
Connectivity
SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
36
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
2.25K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
52-PLCC
Processor Series
AT89x
Core
8051
Data Bus Width
8 bit
Data Ram Size
2304 B
Interface Type
UART, SPI
Maximum Clock Frequency
60 MHz
Number Of Programmable I/os
36
Number Of Timers
3
Operating Supply Voltage
3 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
Package
52PLCC
Device Core
8051
Family Name
89C
Maximum Speed
60 MHz
For Use With
AT89OCD-01 - USB EMULATOR FOR AT8XC51 MCU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51AC3-S3SUM
Manufacturer:
Atmel
Quantity:
10 000
AC Parameters
Explanation of the AC
Symbols
124
AT89C51AC3
Each timing symbol has 5 characters. The first character is always a “T” (stands for
time). The other characters, depending on their positions, stand for the name of a signal
or the logical status of that signal. The following is a list of all the characters and what
they stand for.
Example: T
T
(Load Capacitance for port 0, ALE and PSEN = 60 pF; Load Capacitance for all other
outputs = 60 pF.)
Table 73, Table 76 and Table 79 give the description of each AC symbols.
Table 74, Table 78 and Table 80 give for each range the AC parameter.
Table 75, Table 78 and Table 81 give the frequency derating formula of the AC parame-
ter for each speed range description. To calculate each AC symbols: Take the x value
and use this value in the formula.
Example: T
x = 30 ns
T = 50 ns
T
A
CCIV
T
= -40°C to +85°C; V
LLPL
= 4T - x = 170 ns
= Time for ALE Low to PSEN Low.
AVLL
LLIV
and 20 MHz, Standard clock.
= Time for Address Valid to ALE Low.
SS
= 0V; V
CC
= 3V to 5.5V; F = 0 to 40 MHz.
4383D–8051–02/08