Specifications of PIC24HJ64GP506-E/PT

Core Processor
PIC
Core Size
16-Bit
Speed
40 MIPs
Connectivity
CAN, I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
53
Program Memory Size
64KB (22K x 24)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 18x10b/12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
64-TFQFP
For Use With
DM300024 - KIT DEMO DSPICDEM 1.1MA240012 - MODULE PLUG-IN PIC24H 100QFPDV164033 - KIT START EXPLORER 16 MPLAB ICD2DM300019 - BOARD DEMO DSPICDEM 80L STARTERDM240001 - BOARD DEMO PIC24/DSPIC33/PIC32AC164327 - MODULE SKT FOR 64TQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC24HJ64GP506-E/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
REGISTER 20-1:
© 2009 Microchip Technology Inc.
bit 3
bit 2
bit 1
bit 0
SIMSAM: Simultaneous Sample Select bit (only applicable when CHPS<1:0> = 01 or 1x)
When AD12B = 1, SIMSAM is: U-0, Unimplemented, Read as ‘0’
1 = Samples CH0, CH1, CH2, CH3 simultaneously (when CHPS<1:0> = 1x); or
0 = Samples multiple channels individually in sequence
ASAM: ADC Sample Auto-Start bit
1 = Sampling begins immediately after last conversion. SAMP bit is auto-set
0 = Sampling begins when SAMP bit is set
SAMP: ADC Sample Enable bit
1 = ADC sample/hold amplifiers are sampling
0 = ADC sample/hold amplifiers are holding
If ASAM = 0, software may write ‘1’ to begin sampling. Automatically set by hardware if ASAM = 1.
If SSRC = 000, software may write ‘0’ to end sampling and start conversion. If SSRC ≠ 000,
automatically cleared by hardware to end sampling and start conversion.
DONE: ADC Conversion Status bit
1 = ADC conversion cycle is completed.
0 = ADC conversion not started or in progress
Automatically set by hardware when analog-to-digital conversion is complete. Software may write ‘0’
to clear DONE status (software not allowed to write ‘1’). Clearing this bit will NOT affect any operation
in progress. Automatically cleared by hardware at start of a new conversion.
Samples CH0 and CH1 simultaneously (when CHPS<1:0> = 01)
ADxCON1: ADCx CONTROL REGISTER 1 (where x = 1 or 2) (CONTINUED)
PIC24HJXXXGPX06/X08/X10
DS70175H-page 205