OPTOCOUPLER AMP 100KHZ 8-SMD

HCPL-7800-500E

Manufacturer Part Number
HCPL-7800-500E
Description
OPTOCOUPLER AMP 100KHZ 8-SMD
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-7800-500E

Amplifier Type
Isolation
Number Of Circuits
1
-3db Bandwidth
100kHz
Current - Input Bias
500nA
Voltage - Input Offset
300µV
Current - Supply
10.9mA
Current - Output / Channel
16mA
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SMD Gull Wing
No. Of Channels
1
Optocoupler Output Type
Analog
Input Current
16mA
Output Voltage
3.8V
Opto Case Style
SMD
No. Of Pins
8
Input Current Max
5µA
Isolation Voltage
3.75kV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Slew Rate
-
Gain Bandwidth Product
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-7800-500E
Quantity:
1 000
Part Number:
HCPL-7800-500E
Manufacturer:
AVAGO
Quantity:
1
Part Number:
HCPL-7800-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-7800-500E
Quantity:
10 000
Part Number:
HCPL-7800-500E/HCPL7800-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2): 2003-01.
Regulatory Information
The HCPL-7800(A) has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings which
must be ensured by protective circuits within the application. Surface Mount Classification is
Class A in accordance with CECC00802.
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Cata-
log, under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-2) for a detailed descrip-
tion of Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of PS and IS on ambient temperature.

Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
Input to Output Test Voltage, Method a
Highest Allowable Overvoltage
Safety-limiting values—maximum values
allowed in the event of a failure.
Insulation Resistance at T
(Transient Overvoltage t
for rated mains voltage 300 Vrms
for rated mains voltage 600 Vrms
V
t
V
t
Case Temperature
Input Current
Output Power
m
m
IORM
IORM
= 1 sec, Partial discharge < 5 pC
= 60 sec, Partial discharge < 5 pC
x 1.875 = V
x 1.5 = V
[3]
[3]
PR,
PR,
Type and Sample Test,
100% Production Test with
ini
S
, V
= 10 sec)
IO
= 500 V
[2]
[2]
[1]
UL
Approved under UL 1577, component
recognition program up to V
CSA
Approved under CSA Component Acceptance
Notice #5, File CA 88324.
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S,OUTPUT
S
Characteristic
I-IV
I-III
55/100/21
2
891
1670
1336
6000
175
400
600
>10
800
700
600
500
400
300
200
100
0
9
0
ISO
25
T
= 3750 Vrms.
A
50
- CASE TEMPERATURE -
75
100
Unit
V
V
V
V
°C
mA
mW
PEAK
PEAK
PEAK
PEAK
P S (mW)
I S (mA)
125
150
o
C
175
200

Related parts for HCPL-7800-500E