MB3793-27APNF-G-JN-ER6E1 Fujitsu Semiconductor America Inc, MB3793-27APNF-G-JN-ER6E1 Datasheet - Page 11

IC PWR VOLT MON 27A WD 8SOP

MB3793-27APNF-G-JN-ER6E1

Manufacturer Part Number
MB3793-27APNF-G-JN-ER6E1
Description
IC PWR VOLT MON 27A WD 8SOP
Manufacturer
Fujitsu Semiconductor America Inc
Type
Simple Reset/Power-On Resetr

Specifications of MB3793-27APNF-G-JN-ER6E1

Number Of Voltages Monitored
1
Output
CMOS Inverted
Reset
Active Low
Reset Timeout
30 ms Minimum
Voltage - Threshold
2.7V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
865-1023-2
5. Clock pulse input supplementation (Positive clock pulse)
1. Positive clock pulse input
See “1. Basic operation (positive clock pulse)” under “ DIAGRAM.”
2. Negative clock pulse input
See “2. Basic operation (negative clock pulse)” under “ DIAGRAM.”
The MB3793 operates in the same way whether it inputs positive or negative pulses.
3. Clock monitoring
To use the MB3793 while monitoring only one clock, connect clock pins CK1 and CK2.
Although the MB3793 operates basically in the same way as when monitoring two clocks, it monitors the clock
signal at every other input pulse.
See “3. Single-clock input monitoring (positive clock pulse)” under “ DIAGRAM.”
4. Description of Operations
The numbers given to the following items correspond to numbers (1) to (13) used in “ DIAGRAM.”
OPERATION SEQUENCE
(1) The MB3793 outputs a reset signal when the supply voltage (V
(2) If V
Note : The MB3793 watchdog timer monitors Clock1 (CK1) and Clock2 (CK2) pulses alternately.
reset hold time setting capacitor C
2.76 V.
When a CK2 pulse is detected after detecting a CK1 pulse, the monitoring time setting capacity (C
switches to charging from discharging.
When two consecutive pulses occur on one side of this alternation before switching, the second pulse
is ignored.
In the above figure, pulse *1 and *2 are ignored.
CC
CTW
CK1
CK2
reaches or exceeds the rise-time detected voltage V
V
V
H
L
TP
. At this time, the output remains in a reset state. The V
*1
*2
SH
, the MB3793 starts charging the power-on
CC
) reaches about 0.8 V (V
MB3793
SH
CCL
value is about
)
-27A
TW
)
11