MAX692ACPA+ Maxim Integrated Products, MAX692ACPA+ Datasheet - Page 2

IC MPU SUPERVISORY CIRCUIT 8-DIP

MAX692ACPA+

Manufacturer Part Number
MAX692ACPA+
Description
IC MPU SUPERVISORY CIRCUIT 8-DIP
Manufacturer
Maxim Integrated Products
Type
Battery Backup Circuitr
Datasheet

Specifications of MAX692ACPA+

Number Of Voltages Monitored
1
Output
Push-Pull, Totem Pole
Reset
Active Low
Reset Timeout
140 ms Minimum
Voltage - Threshold
4.4V
Operating Temperature
0°C ~ 70°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Monitored Voltage
4.4 V
Undervoltage Threshold
4.25 V
Overvoltage Threshold
4.5 V
Manual Reset
No
Watchdog
Yes
Battery Backup Switching
Yes
Power-up Reset Delay (typ)
280 ms
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1 V
Supply Current (typ)
350 uA
Maximum Power Dissipation
727 mW
Mounting Style
Through Hole
Maximum Operating Temperature
+ 70 C
Chip Enable Signals
No
Minimum Operating Temperature
0 C
Output Type
Active Low or Push-Pull
Power Fail Detection
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Terminal Voltage (with respect to GND)
Input Current
Output Current
ELECTRICAL CHARACTERISTICS
(V
T
Microprocessor Supervisory Circuits
ABSOLUTE MAXIMUM RATINGS
Note 1: The input voltage limits on PFI and WDI may be exceeded if the current into these pins is limited to less than 10mA.
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
2
Operating Voltage Range,
V
Supply Current (Excluding I
I
(Excluding I
V
V
V
Battery Switch Threshold, V
to V
Battery Switchover Hysteresis
Reset Threshold
Reset Threshold Hysteresis
Reset Pulse Width
RESET Output Voltage
V
V
All Other Inputs (Note 1) . . . . . . . . . . . . . . . . -0.3V to (V
V
V
GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20mA
V
All Other Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20mA
A
SUPPLY
CC
BATT
CC
OUT
OUT
CC
BATT
CC
BATT
OUT
= T
_______________________________________________________________________________________
, V
BATT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mA
= 4.75V to 5.5V for MAX690A/MAX802L/MAX805L, V
MIN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 6.0V
. . . . . . . . . . . . . . . . . . . Short-Circuit Protected for up to 10sec
Output
in Battery-Backup Mode
Standby Current (Note 3)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 6.0V
BATT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50mA
in Battery-Backup Mode
to T
(Note 2)
PARAMETER
OUT
MAX
)
, unless otherwise noted.)
CC
OUT
)
SYMBOL
I
SUPPLY
V
t
RS
RT
CC
MAX69_AC, MAX802_C
MAX805LC
MAX69_AE/M, MAX80_ _E
MAX69_AC, MAX802_C
MAX69_AE/M, MAX802_E, MAX805LE/M
V
V
5.5V > V
V
I
I
I
V
MAX690A, MAX802L, MAX805L
MAX692A, MAX802M
MAX802L, T
MAX802M, T
I
I
MAX69_AC, MAX802_C, V
I
MAX69_AE/M, MAX802_E,
V
OUT
OUT
OUT
SOURCE
SINK
SINK
CC
BATT
BATT
CC
CC
+ 0.3V)
< V
= 0V,
= 1.2V, I
= 5mA
= 50mA
= 250µA, V
= 3.2mA
= 50µA
= 2.8V
+0.2V
RT
= 800µA
CC
>
A
CONDITIONS
A
SINK
CC
= +25°C, V
= +25°C, V
Rate of Rise, V
Continuous Power Dissipation
Operating Temperature Ranges:
Storage Temperature Range . . . . . . . . . . . . . . . . . . -65°C to +160°C
Lead Temperature (soldering, 10sec) . . . . . . . . . . . . . . . . . . +300°C
CC
Plastic DIP (derate 9.09mW/°C above +70°C) . . . . . . . . 727mW
SO (derate 5.88mW/°C above +70°C) . . . . . . . . . . . . . . . . 471mW
CERDIP (derate 8.00mW/°C above +70°C) . . . . . . . . . . . 640mW
MAX69_AC_ _, MAX80_ _ C_ _ . . . . . . . . . . . . . . . . . . 0°C to +70°C
MAX69_AE_ _, MAX80_ _ E_ _ . . . . . . . . . . . . . . . . -40°C to +85°C
MAX69_AMJA, MAX805LMJA . . . . . . . . . . . . . . . . -55°C to +125°C
= 4.5V to 5.5V for MAX692A/MAX802M, V
= 100µA
< V
T
T
T
T
Power-up
Power-down
A
A
A
A
BATT
= +25°C
= T
= +25°C
= T
CC
CC
CC
MIN
MIN
- 0.2V
falling
falling
= 1.0V
CC
to T
to T
, V
MAX
MAX
BATT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100V/µs
V
V
V
V
CC
CC
BATT
CC
4.50
4.25
4.55
4.30
MIN
-0.1
-1.0
140
1.0
1.1
1.2
- 0.05 V
- 0.5
- 1.5
- 0.1 V
TYP
0.05
4.65
4.40
V
200
200
200
-20
BATT
CC
20
40
40
CC
- 0.025
- 0.25
- 0.02
MAX
0.02
0.02
4.75
4.50
4.70
4.45
350
500
280
5.5
5.5
5.5
1.0
5.0
0.4
0.3
0.3
BATT
UNITS
= 2.8V,
mV
mV
mV
ms
µA
µA
µA
V
V
V
V
V

Related parts for MAX692ACPA+